Process SamplerType S230 pages
DOPAK® Process Sampler Type S23
configuration with threaded connections (D1)
The ability to purge the sample point ensures optimal retrieval
of a representative, contamination free sample. The S23 type
sampler provides a system purge and needle purge in addition
to a fixed sample volume.
The unique design offers a one handle operation by multiple
valves, allowing for sampling independent of the process
conditions. These features provide sample accuracy and safety.
1 OPERATION/FUNCTION
0 - off
Provide a new septum on
your sample bottle. Insert the
bottle, with cap and septum
into the sleeve until the
septum is pierced by the
needles. Put the bottle
retaining clip in place.
1 - system purge
Turn the handle to the “bypass”
position, allowing a continuous
flow of liquid through the
sampler to ensure representative
sampling.
This position can be held for any
required time.
2 - sample
Turn the handle to the “sample”
position, allowing the product to
flow into the sample bottle.The
fixed volume sample chamber
determines the amount of
sample.The inert gas will assist
the sample to flow into the
bottle and will purge the
sampler.
This position can be held for any
required time.
3 - off
Turn the handle to the “off”
position. Remove the bottle
retaining clip and pull the
bottle out from the sleeve.The
septum reseals automatically.
2 TYPICAL P & ID
"