PSLC10 pages
DC power supply linear regulated
for 115 / 230VAC input voltage
type PSLC1
Technical data
Input data
45 - 66 Hz
115Volt / 230Volt
-15% to +15%
at 115VAC max. 330mA / at 230VAC max. 165mA
20 mSek. typ.
Input voltage AC
Inputvoltage tolerance
Input current at nominal load
Input current peak
Protective circuit
Hold-up time
Output data
Output voltage UNominal
Output current INominal
Current limiting
Residual ripple (100Hz)
see table below
see table below
1,1 x IN
< 10mV
Control data
< 200mV with load variation 10...90%
< 10mV with supply variation ±10%
< 50µSek. with load variation 10...90%
Control deviation load
Control deviation supply
Control time
Operating data
Duty circle
Operating temperature range
Derating
Storage temperature range
Cooling
- konform
100%
- 30°C to +80°C
from 40°C
-30°C...+105°C
selfcooling
recommended respective distance 15mm each
Safety devices
Fuse for input
Fuse for output
Overload protection
MTBF
at 115VAC 0,5A delayed / at 230VAC 0,25A delayed
not necessary - cont. short-circuit proof
integrated into device
>380.000 h
Safety data
5 kVac in accordance to VDE 0551
Primary circuit - secondary circuit 3,75 kVac
acc. to VDE 0806 / IEC 380
in acc. to VDE 0871 B, EN 55022/B
Class 2 (EN 60950)
PELV (EN60204), SELV (EN 60950)
95% relative humidity, yearly average dewing
allowed for use in tropical ambient
IP 65
IP 20 (VGB4)
>30g at 33Hz in X,Y and Z,
acc. to IEC 60068-2-27
Test voltage transformer
High voltage resistance
Output separated according to VDE 0551
Degree of EMI suppresion
Protection class
Extra low safety potential
Ambient humidity
Extra low safety potential
PELV (EN 60204), SELV (EN 60950)
Overload- and open circuit protected
short circuit proof
Parallel connection possible
Protected against pol-permutation at the output
Protective class enclosure
Protective class terminals
Vibration proof
Applied construction regulations
Suitable for the tropics - Epoxy resin casted
VDE 0100, 0110, 0113, 0551, 0160/W2, 0806
IEC 60950,IEC61000-6-1-2-3-4,IEC60068-2-3
IEC 60068-2-11-52,IEC 60529,IEC 380
EN60950,EN50081-1,EN50081-2,EN50082-1
EN61000-6-1-2-3-4,EN50178,EN55022
EN55011,EN61000-3-3,EN50204,EN61558-2-17
EN60204,EN60529,EN61000-4-2-3-4-5-6-8-11
EN60068-1,EN60068-2-1-2-3-6-27-30
EN45501,EN50021
CSA-C 22.2 / UL60950, UL508, UL1950
according to VDE
IEC
Operating status shown by LED
EN
Safety acc. to VDE, EN, UL, CSA
CSA / UL
Mechanics
Mounting
Nominal output voltage
On rails acc. to DIN46277
or wall mounting with screws
15,0VDC
24,0VDC
Range of adjustment
output voltage
-
-
-
-
Type
PSLC051
PSLC121
PSLC151
PSLC241
1,0Amp.
1,0Amp.
1,0Amp.
1,0Amp.
Power
5Watt
12Watt
15Watt
24Watt
Efficiency
29%
42%
48%
58%
Nominal output current
Dimensions
(W x H x D)
55x75x110 55x75x110 55x75x110 55x75x110
Weight
approx.
0,84kg
approx.
0,84kg
approx.
0,84kg
approx.
0,84kg
Order-No.
58006
58026
58016
58025
P.O. Box 1521
22905 Ahrensburg Germany
11
0
12,0VDC
75
5,0VDC
Phone : +494102 - 42082
Telefax: +494102 - 40930
E-Mail : info@feas.de
Internet: www.feas.de