LOADING
AC/DC Modules Datasheets PFC 350 W 115/220Vac Series0 pages
نسخه متنی
"Hi-Rel AC/DC PFC MODULEHGMM-350 : 350W POWER nn
Permanent input range : 85 - 265 VAC
Օ Frequency range : 45-65Hz
MIL-STD-704, MIL-STD-1399Օ Low input current harmonic distorsion < 10%
Output Power : 350W
Օ Active inrush current limitation
Inhibition function nn
AC/DC power factor corrected module designed
to be compatible with the single phase input
bus 115/230VAC 50/60Hz frequency.
The modules accept an AC input voltage ranging
from 85Vac to 265Vac and include active power
factor corrector that enables a very low level of
current harmonic distorsion.
The HGMM-350 is compliant with numerous
military standards requirements among them
with : Օ the US military standard MIL-STD-1399A/B : - permanent input range : 107-123Vac
- transient : 92Vac/2s - 138Vac/2s the US military standard MIL-STD-704E/F : - permanent input range : 108-118Vac
- transient : 80Vac/10ms - 180Vac/100ms Օ the US military standard MIL-STD-1399 The HGMS-350-Y-T module includes a soft startan active inrush current limitation, a permanent
short circuit protection and an inhibit function.
The soft-start/active current limitation eliminates
inrush current during start-up, the short circuit
protection protects the module against short-
circuits of any duration by a shut down and
restores to normal when the overload is removed.The HGMS-350-Y-T output voltage is set to 420Vdccompatible with GAIA Converter high input vol-
tage series of DC/DC converter and operates
with a hold-up capacitance to allows transparency
time and ripple reduction.The design has been carried out withsurface mount components and is manufactured
in a fully automated process to guarranty high
quality. Every module is tested with a Gaa
Converter automated test equipment. The mo-
dules are potted with a bi-component thermal
conductive compound and packaged in a metalic
case to ensure the modules integrity under high
environmental conditions. nn4 nn
Hi-RelGrade
nn115/230 VAC Universal Power Factor CorrectedFrequency 45-65HzNon Isolated OutputMetallic Case nn AC/DC Non Isolated Power Factor Corrected ModuleՕ 115/230 VAC single phasePermanent input range : 85 - 265 VAC
Օ Frequency range : 45-65Hz
MIL-STD-704, MIL-STD-1399Օ Low input current harmonic distorsion < 10%
Output Power : 350W
Օ Active inrush current limitation
Inhibition function nn
1- General
nnThe GAIA Converter HGMM-350 universal inputmodule HGMS-350-Y-T designates a non isolatedAC/DC power factor corrected module designed
to be compatible with the single phase input
bus 115/230VAC 50/60Hz frequency.
The modules accept an AC input voltage ranging
from 85Vac to 265Vac and include active power
factor corrector that enables a very low level of
current harmonic distorsion.
The HGMM-350 is compliant with numerous
military standards requirements among them
with : Օ the US military standard MIL-STD-1399A/B : - permanent input range : 107-123Vac
- transient : 92Vac/2s - 138Vac/2s the US military standard MIL-STD-704E/F : - permanent input range : 108-118Vac
- transient : 80Vac/10ms - 180Vac/100ms Օ the US military standard MIL-STD-1399 The HGMS-350-Y-T module includes a soft startan active inrush current limitation, a permanent
short circuit protection and an inhibit function.
The soft-start/active current limitation eliminates
inrush current during start-up, the short circuit
protection protects the module against short-
circuits of any duration by a shut down and
restores to normal when the overload is removed.The HGMS-350-Y-T output voltage is set to 420Vdccompatible with GAIA Converter high input vol-
tage series of DC/DC converter and operates
with a hold-up capacitance to allows transparency
time and ripple reduction.The design has been carried out withsurface mount components and is manufactured
in a fully automated process to guarranty high
quality. Every module is tested with a Gaa
Converter automated test equipment. The mo-
dules are potted with a bi-component thermal
conductive compound and packaged in a metalic
case to ensure the modules integrity under high
environmental conditions. nn4 nn
2- Product Selection
nnHGMS - 350 - (/T) and/or (/S)
(/T) : option for -55C start up operating temperature.(/S) : option for screening and serialization Input Voltage Range Output Y : 85-265 VAC / 50/60 Hz T : 420 VDC >
REDEFINING THE SOURCE OF POWER
Gaia Converter FC06-033.11/08 Revision A For locations, phone, fax, E-Mail see back cover >
"