Electromagnetic pumps ED0 pages
Application fields :
Electromagnetic pump
EDS 03
Technical data
Household equipment
Medical and laboratory devices
Printing systems
Lubrication
The EDS 03 is a new generation of diaphragm
pump ideally suited for transfer of various
aggressive or light polluted liquids. Low flow
and low pressure but the pump is able to run
dry and work with air, for sampling or
circulation for example.
No maintenance and long lifetime, give it a try !
You won't be disappointed.
Nominal rated data :
Maximum pressure
Maximum flow rate
: 0.3 [bar]
: 7 [l/h]
Maximum suction height : 1.5 [m]
Viscosity range
: 1…600 [mm2/s]
Tension
: 230 [V]~ (110 [V], 24 [V],
12 [V])
Filter
Frequency
Electrical connection
Power
Weight
Temperature
Insulation
: Mesh 100
: 50 [Hz], (60 [Hz])
: 3 x 6.3 [mm] x 0.8 [mm]
: 18 [W]
: ~90 [g]
: 1...50 [°C]
: Class F100% ED / 20 [°C]
with heat sink
(Class H on request)
Approvals
EMC
RoHS
Class I
: EC conform to
EN603351 (ED.4),
CB cert. Nr. CH4364,
(UL on request)
: Conform to 2004/108/EC
: Conform to 2002/95/EC
GOTEC SA Rue des casernes 59 CH1950 SION Tel. +4127205 72 05 Fax:06 www.gotec.ch sales@gotec.ch