Sinpo (Guiyang Xintian) JX13C toolmaker's microscope for high accuracy dimension measurement0 pages
Sinpo
JX13G
Image Processing Universal Toolmaker's Microscope
Characteristics
© Taking imported high precision grating scale as the measuring
units, with low heating dissipation , corrosion resistance, pollution
resistance, good shock proof performance etc.
© Equipped with powerful image processing software, can complete
complicated measuring task; software data can communicate with
CAD to complete surveying and mapping work.
© Eyepiece optical system is acting as an auxiliary viewing port,
could be switched quickly.
© Equipped with digital display rotary table and height measuring
device, all measured results of angles and heights can be displayed
digitally.
Q LED cold-light source is adopted for the whole lighting device,
with low heating dissipation and long life.
© Main microscope can deflect left and right, suitable for the
measurement of spiral parts.
Technical Parameters
Worktable
Range of measurement (mm)
X-coordinate: 200 Y-coordinate: 100
Resolution of X- and Y-coordinate measurement: 0.0002mm
Accuracy of the X- and Y-coordinate: (1+L/100) p m, of which, L =
length of the measured workpiece, unit: mm
Area of square worktable (mm): 260 x 270
Maximum height of the stored workpiece on the square worktable
(mm): 140
Maximum load of the instrument: 40kg
Microscope upright column
Angle tilting range: ±12°
Angle tilting division value: 30'
Objective
Objective magnification | 1x | 3x | 5x |
Work distance ( mm ) | =82 | =70 | =49 |
Visual field (mm) | 6.0x4.0 | 2.0x1.5 | 1.5x0.9 |
Screen image range ( mm ) | 1/2" =5.2x4.1 | 1/2 "=1.7x1.4 | 1/2" =1.0x0.8 |
_ | 1/3'-4.1x3.1 | 1/3"=1.4x1.0 | 1/3"=0.8x0.6 |
Tailstock
Maximum diameter gripped by the tailstock: $ 100 mm
Maximum length gripped by the tailstock: 700 mm
Higher Tailstock
Maximum diameter gripped by the higher tailstock: <|> 250 mm
Maximum length gripped by the higher tailstock: 200 mm
Digital display index head
Angle measuring range: 0° -360°
Resolution ratio of the angle measuring: 5"
Accuracy of the angle measuring: 30"
CCD camera head
1/2" or 1/3" black & white (or colored) CCD
Number of pixel: 795x596
Optical position indicator
Minimum detection aperture: (J> 5 mm
Maximum detection depth: 15mm Metering force: 0.1N
Locating stability: 0.001mm
Limit error gauged for head diameter: 0.0005mm
Ambient environment of the instrument service:
Room temperature: 20°C ± 1°C
Relative humidity: Not more than 60%
Overall size of the principal machine of the instrument:
1300 x 1250x800
Weight of the principal machine of the instrument: 450kg
29
"