HS-160 Series 0 pages
HS-160 Sries Velocity Sensor 2 Pin MS Connector, Velocity Accelerometer Typical Applications Proven use in vibration monitoring for offline applications using commercially available data collectors and online monitoring Systems in the fields of Building Services, Civil Engineering, Paper and Pulp, Mining, Metals Manufacture, Utilities, Automotive, Water and Waste Treatment, Pharmaceutical, Aerospace, etc. Protecting... Fans, Motors, Pumps, Compressors, Centrifuges, Conveyers, Air Handlers, Gearboxes, Rolls, Dryers, Presses, Cooling, HVAC, Spindles, Machine Tooling, Process Equipment and many more. I Technical Performance Mounted Base Rsonance Sensitivity Frequency Response Isolation Measurement Range Transverse Sensitivity 22 kHz (nominal) 4 mV/mm/s ±10% Nominal 80 Hz at 22 °C 2 Hz to 6 kHz ±3 dB Base isolated 1000 mm/s pk Less than 5% ■ Electrical Electrical Noise Current Range Bias Voltage Settling Time Output Imp驩dance Case Isolation 0.1 mg max 0.5 mA to 8 mA 10-12 Volts DC 2 seconds 200 Ohms max. >108Ohms at 500 Volts 1 Environmental Operating Temprature Range Sealing Maximum Shock Emissions Immunity -55 to 140 °C IP67 5000 g EN61000-6-4:2007 EN61000-6-2:2005 1 Mechanical Case Material Sensing Elment/Construction Mounting Torque Weight Maximum Cable length Mating Connector Mounting Threads Options Stainless Steel PZT/Compression 8 Nm 110 gms (nom) 1000 m驨tres HS -AA004 See 'How to order' table Intgral cable, temprature output, various connector assemblies, other sensitivities H Hansford Sensors Excellence in Vibration Monitoring Tel: +44(0)845 680 1957 Fax: +44(0)845 680 1958 Email: sales@hansfordsensors.com Web: www.hansfordsensors.com
"