ProCheck-S Solid Validation Turbidity Standard0 pages
Water Quality Measurement Solutions A Watts Water Technologies Company
nnnnSolid Validation Turbidity Standard
nnnnThe ProCheck Solid Validation Standards are used as a quick and convenient "check" to determine if a Primary Calibration is needed prior
nnnnto the next regularly scheduled primary calibration. Designed for use with HF scientific turbidimeters, they can be used as often as needed
nnnnand will last for many years. Although actual values will be determined with testing, the typical value for the low range ProCheck-S will be
nnnnless than 1 NTU for drinking water and other applications requiring a very low NTU range and the mid range ProCheck-S will typically be
nnnnaround 7 NTU for higher range applications.
nnnnHow do they work?
nnnnPerform a full primary instrument turbidity calibration using the
nnnnnormal procedures for your instrument.
nnnnInsert the ProCheck-S standard into the instrument with the red
nnnnindex mark facing forward.
nnnnTake a reading, record the obtained value and log the result.
nnnnCalculate the +/-10% Min/Max Pass Range and log the results.
nnnnMin value is the obtained value minus 10%, the Max value is the
nnnnobtained value plus 10%
nnnnTo perform a validation check between scheduled
nnnnprimary instrument calibrations:
nnnnInsert the ProCheck-S turbidity standard with the red index mark
nnnnfacing forward.
nnnnTake a reading, note the obtained value and compare it with the
nnnn+/-10% Min/Max Pass Range obtained earlier.
nnnnIf the value falls within the +/-10% Min/Max Pass
nnnninstrument has passed.
nnnnIf the value falls outside the +/-10% Min/Max Pas
nnnnprimary calibration of the instrument is needed.
nnnnAdvantages
nnnn• Can be used with multiple instruments
nnnn• Validate a turbidimeter in just seconds
nnnn• Complies with USEPA Method 180.1 procedures
nnnn• Two year warranty
nnnnOrdering Information
nnnnCat. No. Description
nnnn28335 | ProCheck Low NTU Value (typically less that 1 NTU) - for MicroTOL, Micro 100/1000 |
28336 | ProCheck Mid NTU Value (typically around 7 NTU) - for Micro TOL, Micro 100/1000 |
All units include one ProCheck-S standard, log sheet, microfiber cloth, instruction sheet and is
nnnnhoused in a hard, protective case.
nnnnLow NTU Mid NTU
nnnnValue Value
nnnnRange the
nnnns Range a full
nnnnProCheck-S
nnnnin case
nnnn3170 Metro Parkway, Ft. Myers FL 33916 e-mail: hfinfo@watts.com
nnnnph: (239)-337-2116 • fax: (239) 332-7643 • toll free: 888-203-7248 www.hfscientific.com
nnnn3-21-2011 Rev 0.1
"