Micro100 Laboratory Turbidimeter0 pages
ft
nnnnWater Quality Measurement Solutions
nnnnA Watts Water Technologies Company
nnnnMicro 1100 Laboratory Turbidimeter
nnnnDesigned to provide the accuracy demanded by today's scientist, the Micro 1100
nnnnLaboratory Turbidimeter is ready to meet the challenge. Features such as the Auto Alert
nnnnCalibration Prompt and the Quick Connection Lamp Module, allow for simple calibration
nnnnand low maintenance. With a resolution of 0.01 NTU at low turbidity readings and an
nnnnextended range to 1,000 NTU, the Micro 1100 is an ideal and affordable tool for research
nnnnas well as routine analytical measurements.
nnnnStandard Features
nnnn• Auto Ranging 0 -1000 NTU
nnnnInstrument senses turbidity level of sample and automatically adjusts to
nnnnthe appropriate measurement.
nnnn• Auto Alert Calibration Prompt
nnnnAutomatically prompts the operator when calibration of the instrument is needed.
nnnn• Simple Calibration Procedures
nnnnCalibration initiated with the push of a button ensures accurate readings
nnnn• RS-232 Output
nnnnDate, time and NTU reading can be captured with a serial printer or data
nnnnrecorder.
nnnnSpecifications
nnnnOptional Features
nnnn• Infrared Light Source Micro 1100 IR
nnnnMeets international standard ISO 7027 for turbidity measurement.
nnnn• Pour Through Assembly
nnnnSave time by pouring your grab sample through the measurement chamber.
nnnn• Reusable ProCaf Calibration Standards
nnnnQuick and easy calibration across all ranges without the need to mix Formazin
nnnnOrdering Information
nnnnCat. No. Description
nnnn20001
nnnn19950
nnnn19952
nnnnMicro 1100 Laboratory Turbidimeter, 120 VAC
nnnnRange: | Auto Ranging from 0 - 1000 NTU |
Measurement Principle: | Nephelometric non-ratio |
Accuracy: | ± 2% of reading plus 0.01 NTU whichever is greater |
Resolution: | 0.01 NTU (0 -9.99 NTU) 0.1 NTU (10-99.9 NTU) 1 NTU (100- 1000 NTU) |
Response Time: | < 6 seconds |
Sample Size: | 30 ml (27ml minimum) |
Light Source: | Quick Connect Tungsten Filament or Infrared |
Operating Temperature: | 32°-122°F(0°-50°C) |
Outputs: | RS-232 Printer Port |
Dimensions: | 10.75 x 10 x 3.75 in. (27.3 x 25.4 x 9.5 cm) |
Weight: | 2.9 lbs. (1.32 kg) |
Safety rating: | UL, CSA, CE |
Micro 1100 Laboratory Turbidimeter, 100 - 240 VAC
nnnnMicro 1100 IR Laboratory Turbidimeter, 100 - 240 VAC
nnnnNote: The Micro 1100 meets performance criteria specified by USEPA
nnnnmethod 180.1 for NTU measurement and ISO7027 (IR version).
nnnnSpecifications subject to change without notice.
nnnnAccessories
nnnn19975 Pour Through Assembly
nnnn39957 froCaf Calibration Set, (0.02,10, & 1000 NTU)
nnnn50051 Cuvettes, 28 x 70mm, 3 pack
nnnn50052 Cuvettes, 28 x 70mm, 10 pack
nnnn50040 Formazin Stock Solution Kit
nnnnOptional Pour Through Assembly
nnnn3170 Metro Parkway, Ft. Myers FL 33916 e-mail: hfinfo@watts.com
nnnnph: (239)-337-2116 • fax: (239) 332-7643 • toll free: 888-203-7248 www.hfscientific.com
nnnn8-04-2010 Rev 1
"