40EORZDB0 pages
Model: 40EORZDB
33EFORZDB
KOHLER Power Systems
Diesel
O9001
V#J KOHLER
— POWER SYSTEMS
NATIONALLY REGISTERED
IBB -Q- | |
Lb |
ibr
Generator Weights and Dimensions
Remote
Radiator
Inline
Radiator
Weight—dry, kg (lbs.) 535.2(1180) 571.5(1260)
Length, mm (in.) 1228 (48.4) 1478 (58.2)
Width, mm (in.) 610 (24.0) 650 (25.6)
Height, mm (in.) 876 (34.5) 922 (36.3)
See the drawings on the last page for detailed dimensions.
Generator Ratings
Model
Series
Alternator Voltage
Amps
25°C
Hz (77°F)
kW/kVA
25°C
(77°F) Ph
40EORZDB
4P7
120/208
120/240
120/240
127/220
139/240
220/380
277/480
60
60
60
60
60
60
60
138.8
162.5
120.3
131.2
120.3
76.0
60.1
40/50
39/39
40/50
40/50
40/50
40/50
40/50
4Q7
120/240 60 166.7 40/40
4P7
33EFORZDB
110/190
110/220
110/220
220/380
230/400
240/416
50
50
50
50
50
50
125.3
150.0
108.3
62.7
59.5
57.2
33/41.3
33/33
33/41.3
33/41.3
33/41.3
33/41.3
4Q7
110/220
115/230
220
240
50 150.0
50 143.5
50 150.0
50 137.5
33/33 1
33/33 1
33/33 1
33/33 1
Mobile/Commercial
Generator Set
Engine Features
• Heavy-duty construction
• Engine is compliant with the Environmental Protection
Agency (EPA) requirements
• Water-cooled design
• Diesel fueled
• Four cylinders, turbocharged design
• Four cycle
• Frequency regulation of ±0.5%
• Electric fuel lift pump
Generator Features
• CSA certified, file #LR 955
• Remote start 12-pin connector
• Class H insulation
• Voltage regulation of ±1.5%
• Radio suppression
• Outstanding motor-starting capability
• Sustained short-circuit capability
• Four-point mounting with vibration isolators
• Prototype-tested, factory-built, and production-tested
design
ADC 2100 Advanced Digital Control
Features
• Designed for today's most sophisticated electronics
• Easy to read alpha-numeric display
• Compact, integrally mounted control
• Potted boards/sealed connectors for maximum
corrosion protection
• SAE J1939 CAN bus output
• Remote monitoring of up to 13 fault conditions
• Membrane keypad for configuration and adjustment
• Programmed crank cycle
RATINGS: All single-phase units are rated at 1.0 powerfactor. All three-phase units are rated at 0.8 powerfactor. Mobile continuous ratings per ISO 3046 and ISO 8528-1. Obtain technical information
bulletin (TIB-101) on ratings guidelines for complete ratings definitions. GENERAL GUIDELINES FOR DERATING: ALTITUDE: Derate 0.8% per 100 m (328 ft.) elevation above 200 m (656 ft.).
TEMPERATURE: Derate 6.0% per10°C (18°F) temperature above 25°C (77°F).
Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local
Kohler® generator set distributor for availability.
G3-46 (40EORZDB) 5/13e
"