IMPULSE®?G+/VG+ Series 4 Full Brochure0 pages
CAPABILITIES
IMPULSE®•G+ Series 4
Ratings
Class of Service
200-240 Vac, 3.0 to 415 AMP (0.75 to 150 HP)
400-480 Vac, 1.8 to 605 AMP (0.75 to 500 HP)
575-600 Vac, 1.7 to 200 AMP (1 to 200 HP)
CMAA Class A-F Service
AISE TR6 Class 1 to 4
ASME HST – 4M H1 to H5
Speed Range
40:1 in V/F Mode (15 preset V/F Patterns, 1 Adjustable)
200:1 in Open Loop Vector Mode
Speed Control Methods
Up to 17 Distinct Speeds (Stepped)
2-Step Infinitely Variable
3-Step Infinitely Variable
Analog Signal (0–10 Vdc, 4–20 mA, ±10 Vdc)
Digital Pulse Train Input (32 KHz Max)
Radio Drive Serial Interface (RDSI)
Programmable Terminals
(8) 120 Vac Inputs
(3) Digital Dry Contact Relay Outputs (1A Max @ 250 Vac, 1A Max @ 30 Vdc,
Form A)
(1) Dedicated Fault Relay Output (1A Max @ 250 Vac, 1A Max @ 30 Vdc, Form C)
(3) Analog Inputs (0-10 Vdc and ±10 Vdc (20K ), 4-20ma (250))
(2) Analog Outputs (0-10 Vdc and ±10 Vdc Max Current 2mA, 4-20ma (500))
(Consult factory for additional analog/digital input/output option cards)
Certification
UL, cUL, CSA (CE available upon request)
Rated input power supply volts
3-phase 200–240 Vac, 380–480 Vac, or 500-600
Vac; 50 or 60 Hz and frequency
Allowable input voltage fluctuation
+10% or -15% of nominal, 3-phase
Allowable input frequency fluctuation ±5% of nominal
Control method
Fully digital; sine-wave, V/F control, open loop vector
control, flux vector control
Maximum output voltage (Vac)
Max output voltage 3-phase,
200/208/230/240/380/400/415/440/460/480
500/575/600V (proportional to input voltage)
Rated output frequency (Hz)
0 to 150 Hz (consult factory for applications
above 150 Hz)
Output frequency accuracy
0.01% — with digital reference command, -10°
to 40°C;
0.1% — with analog reference command;
10 bits/10V; 25°C, ±10°C
Traverse Motions
Worm Gear and Mechanical Load Brake Hoists
IMPULSE®•VG+ Series 4
Ratings
Class of Service
Speed Range
Speed Control Methods
Programmable Terminals
Applications
200-240 Vac, 3.0 to 415 AMP (0.75 to 150 HP)
400-480 Vac, 1.8 to 605 AMP (0.75 to 500 HP)
575-600 Vac, 1.7 to 200 AMP (1 to 200 HP)
CMAA Class A-F Service
AISE TR6 Class 1 to 4
ASME HST – 4M H1 to H5
1500:1in Flux Vector Mode
Up to 17 Distinct Speeds (Stepped)
2-Step Infinitely Variable
3-Step Infinitely Variable
Analog Signal (0–10 Vdc, 4–20 mA, ±10 Vdc)
Digital Pulse Train Input/Output (32 KHz Max)
Radio Drive Serial Interface (RDSI)
(8) 120 Vac Inputs
(3) Digital Dry Contact Relay Outputs (1A Max @ 250 Vac, 1A Max @ 30 Vdc,
Form A)
(1) Dedicated Fault Relay output (1A Max @ 250 Vac, 1A Max @ 30 Vdc, Form C)
(3) Analog Inputs (0-10 Vdc and ±10 Vdc (20K), 4-20ma (250))
2) Analog Outputs (0-10 Vdc and ±10 Vdc Max Current 2mA, 4-20ma (500))
(1) Single line driver/open collector encoder option card with 5/12 Vdc (200ma)
power supply
(Consult factory for additional analog/digital input/output and encoder option cards)
Traverse Motions (Consult factory)
Non-Mechanical Load Brake Hoists
Frequency reference resolution
0.01 Hz
Overload capacity
150% of rated load for 1 minute
Remote frequency reference sources
0–10 Vdc (20); 4–20 mA (250); ±10 Vdc; serial
(RS-485)
Acceleration/deceleration times
0.1 to 25.5 sec — 4 sets; 8 parameters are
independently adjustable
Braking torque
150% or more with dynamic braking (optional)
Electronic thermal overload relay; UL recognized (I2T)
Overcurrent protection level (OC)
200% of rated current
UNSURPASSED
PRODUCT SUPPORT
THE NEXT GENERATION OF
CRANE PERFORMANCE
As always, you can count on Magnetek and
IMPULSE® drives to help you achieve the maximum
performance and reliability of your overhead
material handling system, including:
•
•
•
•
Three-year warranty
Magnetek Service Technicians on-call 24/7/365
On-site and in-house product training programs
Fully tested prior to shipment
Digital: 0.01 Hz; analog: 0.03 Hz (at 60 Hz)
Output frequency resolution
Motor overload protection
Applications
NEW!
Specification Value and Information
for all IMPULSE®• G+ and VG+
Series 4 Models
Circuit protection
For more information, contact Magnetek
Material Handling or your local Magnetek
Sales Representative.
Ground fault and blown-fuse protection
Overvoltage protection level
For maximum control exibility, match the
IMPULSE•G+/VG+ Series 4 with SBP®/SBP2®
Pendant Pushbutton Stations or Magnetek’s
extensive line of Radio Remote Crane Controls.
410 Vdc (200V), 820 Vdc (400V),
1040 Vdc (600V)
Undervoltage protection level
190 Vdc (200V), 380 Vdc (400V), 475 Vdc (600V)
Heatsink over temperature
Thermostat trips at 105°C
Four quadrant torque limit selection
Separate functions for FORWARD, REVERSE, REGEN; all
selectable from 0–300%
Stall prevention
Separate functions for acceleration, at-speed and
constant horsepower region
Other protection features
Speed deviation, overspeed, mechanical brake failure,
lost output phase, lost input phase, failed-oscillator,
PG-disconnect, mechanical overload, roll-back
detection, internal braking transistor failure, and built
in watchdog
DC bus voltage indication
Charge LED is on until DC bus voltage drops below
50 Vdc
Location
Indoors; requires protection from moisture, corrosive
gases and liquids
Ambient operating temperature
14° to 140°F (-10° to 60°C). Consult factory for high
ambient applications
Storage temperature
-4° to 158°F (-20° to 70°C)
Humidity
95% relative; noncondensing
Vibration
1 G for 10-20 Hz
0.6 G for 20-55 Hz (2003-2180, 4001-4150,
5001-5077)
0.2 G for 20-55 Hz (2215-2415, 4180-41090.
5099-5200)
&
Elevation
3300 ft. (1000m) or less
9900 ft. (3000m) or less with current derating
Safety Standard
UL 508C
A d j u s t a b l e
N49 W13650 Campbell Drive
Menomonee Falls, WI 53051
Toll-Free Phone 800.288.8178
Toll-Free Fax 800.298.3503
Phone 262.783.3500
Fax 262.783.3510
email sales@magnetek.com
WWW.MAGNETEKMH.COM
Pub No. G+_VG+Series4
© Magnetek, Inc. 2011
F r e q u e n c y
C r a n e
C o n t r o l s