Vibration-Resistant Weighing Indicator0 pages
High Performance Digital Filter
Featuring the Newly Developed High-Performance Digital Filter (HPDF) for
Environments with Vibration Issues
A Weighing Indicator that Can Be Used in an Environment with Vibrations
Specifications
Analog unit
External output components
Over 0.15µV/d (d=minimum division)
–35mV to +35mV (–7mV/V to +7mV/V)
DC5V±5%, 120mA
Remote sensing function included
Up to 8 load cells (350Ω) can be connected
Zero; ±0.02µV/˚C (Typ.)
±0.1µV/˚C (Max.)
Span; ±3ppm/˚C (Typ.)
±15ppm/˚C (Max.)
0.005% of F.S.
Less than 0.3µVp-p
–35mV to +35mV (–7mV/V to +7mV/V)
Over 10MΩ
Delta-sigma modulation
Approx. 16,000,000
999,999d (less than 20,000d recommended)
100 times/sec.
Actual load calibration or digital span
calibration not using actual load
Temperature coefficients
Powerful Vibration Cancelling Feature
The High-Performance Digital Filter provides high accuracy/high speed weighing in environments
with vibration problems.
The AD-4410 greatly reduces the costs and maintenance required for anti-vibration equipment
since it copes with vibrations without requiring many mechanical measures. What's more,
conducting weighing while applying vibrations, once an extremely difficult task, is now possible.
The High-Performance Digital Filter only requires one setting. For this reason, optimal settings for
vibration cancelling can be found after just a few tries.
Nonlinearity
Input noise
Maximum measurement voltage
Input impedance
A/D conversion method
Internal resolution
Display resolution
Sampling rate
Calibration
Weight
Control I/O
Basic specifications
Power source voltage
Power consumption
Operating temperature and humidity
Display elements
Measurement data display
Status display
External dimensions
High speed sampling (100 times/second)/high accuracy
Panel cut dimensions
Dust/water protection
Circuits equipped with powerful noise reduction
Options
OP-03
OP-04
OP-11
Note: Only 1 OP-03 or OP-04 can be attached, when OP is attached 20mA
current loop will become unusable.
Accurate linear correction function using high-order
equations
Average holding function
Standard included items
Instruction manual, 7-pin DIN connector, 8-pin DIN connector,
load cell connector, power cable, rubber packing, capacity plate, unit stickers
Note: Please prepare an RS-232C connector for standard serial output (ch1).
A straight cable will be used when connecting to PC or PLC.
Unit: mm
Stand dimensions
Unit: mm
(181)
144
Reliably
accurate!
Powerful vibration-cancelling function
(High Performance Digital Filter)
Dimensions
Digital unit
Can be Calibrated in an Environment with Vibrations
Until now, to conduct calibration, sources of vibration had to be completely stopped, or calibration
had to be conducted on weekends or holidays when machines are not active. However, even in an
environment with vibrations, the AD-4410 can be calibrated at any point, so costs incurred from
stopping production or calibrating on weekends or holidays will disappear.
Vibration-Resistant Weighing Indicator
Standard serial output (ch1)
Standard serial output (ch2)
Weighing display:
7-segment 6-digit green LED
Character height of 14.6mm
Polarity display: 1 green LED
Situational display: 6 red LEDs
Display switchable between net and
gross weight
Display range: 0 to 999,999d
(Select between 1, 2, 5, 10, and 50 for
minimum division “d”)
Units: Affix a “g”, “kg”, or “t” unit sticker
ZERO, STABLE, GROSS, NET, HOLD and
a light which can be given a custom
function by the user
Input sensitivity
Zero adjustment range
Load cell excitation
AD-4410 WEIGHING INDICATOR
0
T
ZERO
STABLE GROSS
NET
HOLD
TARE
F
I/
ON/OFF
ESC
123
72
ZERO
Net/B/G
NET GROSS
ENTER
(118.5)
(6)
Rear panel
C.L./OP
138 +1
0
2-
ø5
CONTROL I/O
80
48
RS-232C
137
Even with
vibrations,
weighing is easy!
67
Fast
response!
68 +0.7
0
LOAD CELL
A&D Company ,Limited
Panel cutout dimensions
70
116
152
50/60Hz 10VA
100 240V
Appearance and/or specifications subject to change for improvement without notice.
Compr
essor
…Clearly a Better Value
3-23-14 Higashi-lkebukuro, Toshima-ku, Tokyo 170-0013 JAPAN
Telephone: 81 (3) 5391-6132 Fax: 81 (3) 5391-6148
http://www.aandd.jp
A&D Engineering, Inc.
1756 Automation Parkway, San Jose, CA 95131 U.S.A.
Telephone: 1 (408) 263-5333 Fax: 1 (408) 263-0119
A&D Australasia Pty Ltd.
32 Dew Street, Thebarton, South Australia 5031 AUSTRALIA
Telephone: 61 (8) 8301-8100 Fax: 61 (8) 8352-7409
A&D Instruments Ltd.
Unit 24/26 Blacklands Way Abingdon Business Park,
Abingdon, Oxon OX14 1DY UNITED KINGDOM
Telephone: 44 (1235) 550420 Fax: 44 (1235) 550485
Ge rman Sales Office
Hamburger Straße 30 D-22926 Ahrensburg, GERMANY
Telephone: 49 (0) 4102 459230 Fax: 49 (0) 4102 459231
A&D Korea Limited
A&D RUS Co., Ltd.
Vereyskaya str.17, Moscow, 121357 RUSSIA
Telephone: 7 (495) 937-33-44 Fax: 7 (495) 937-55-66
A&D Instruments India Private Limited
509 Udyog Vihar Phase V Gurgaon-122 016,
Haryana, INDIA
Telephone: 91 (124) 471-5555 Fax: 91 (124) 471-5599
Manhattan Bldg. 8F, 36-2 Yoido-dong, Youngdeungpo-gu,
Seoul, KOREA
Telephone: 82 (2) 780-4101 Fax: 82 (2) 782-4280
AD4410-ADCC-01-KO1-12801
…Clearly a Better Value
http://www.aandd.jp