RID series0 pages
RID-50
50W Dual Output Switching Power Supply
series
¡½ Features :
¡EIsolated output & GND for CH1,CH2
¡EUniversal AC input / Full range
¡EProtections: Short circuit / Overload / Over voltage
¡ECooling by free air convection
¡ELED indicator for power on
¡E100% full load burn-in test
¡EAll using 105¢J long life electrolytic capacitors
¡EWithstand 300VAC surge input for 5 second
¡EHigh operating temperature up to 70¢J
¡EWithstand 5G vibration test
¡EHigh efficiency, long life and high reliability
¡E3 years warranty
..
SPECIFICATION
MODEL
RID-50A
RID-50B
OUTPUT NUMBER
CH2
CH1
CH2
DC VOLTAGE
5V
12V
5V
24V
RATED CURRENT
6A
2A
4A
1.4A
CURRENT RANGE
0.3 ~ 6A
0.3 ~ 3A
0.3 ~ 6A
0.2 ~ 2A
RATED POWER
OUTPUT
CH1
54W
120mVp-p
80mVp-p
150mVp-p
+8,-4%
53.6W
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 ¡Ó2.0%
¡Ó8.0%
CH1: 4.75 ~ 5.5V
¡Ó2.0%
LINE REGULATION
Note.4 ¡Ó0.5%
¡Ó1.5%
¡Ó0.5%
¡Ó1.5%
LOAD REGULATION
Note.5 ¡Ó0.5%
¡Ó5.0%
¡Ó0.5%
¡Ó5.0%
SETUP, RISE TIME
HOLD UP TIME (Typ.)
60ms/230VAC
VOLTAGE RANGE
88 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
80%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
INPUT
500ms, 20ms/230VAC
1.3A/115VAC
0.8A/230VAC
COLD START 33A/230VAC
LEAKAGE CURRENT
1200ms, 30ms/115VAC at full load
14ms/115VAC at full load
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
81%
<2mA / 240VAC
110 ~ 150% rated output power
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
EMC EMISSION
(Note 6)
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-25 ~ +70¢J (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85¢J, 10 ~ 95% RH
¡Ó0.03%/¢J (0 ~ 50¢J)on +5V output
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25¢J/ 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
172.6Khrs min. MIL-HDBK-217F (25¢J)
99*97*36mm (L*W*H)
0.41Kg; 45pcs/19.5Kg/0.9CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¢J of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:RID-50-SPEC 2012-07-30
"