Process Calibrator M5050 pages
Process Calibrator M505
Current Output 0-22mA, Source/Sink
Voltage Output 0-25V
mV Outputs 0-28mV and 0-560 mV
DIN Thermocouples J, K, N, R, S, T, B, E
RTD Simulator -200 … 850ºC
Resistance Range up to 3kOhm
Multimeter ±2V to ±200V DC and ±100mA
Measurements of fast Transients
Datalogger Function (Option)
Model M505 is a hand held Calibrator-Multimeter for generation of
currents 0-22mA in source or Sink Mode and Voltages 0-25VDC. External
voltages ±2V, ±20V and ±200VDC (selected rages or auto range) and
currents up to ±100mA can be measured simultaneously with the
generated calibrating signals.
Further functions are the generation of mV-Signals, Simulation of DINThermocouples, Generation of Resistances and RTD Temperature Sensors. Up to eight fast input signals Transients- can be measured, memorized and shown at the display as graphics or uploaded to a PC.
Datalogger function for the calibrator output and the multimeter input signals can be activated. Both signals
are stored as tables and shown as graphics at the LCD display. By using the supporting program the data
can be transferred to the PC and shown as tables and graphics.
For fast checking or calibration of Process Transmitters the calibrator output can be used for the input,
whereas the output from the Transmitter will be measured by the multimeter. The results are shown at the
display immediately.
mV Voltages 0-28mV or 0-560mV for calibration of strain gauges amplifiers, transmitters and small signal
instruments. The output voltage can be resolved up to 0.001mV.
Thermocouples J, K, N, R, S, T, B, and E are simulated across the entire DIN ranges. The output is via T/C
plug with automatic compensation of the junction. This can be also switched-off.
RTD Thermometers Pt-100 … 1000 and Ni-1000 are simulated across the entire DIN range.
Resistance Source is a generator of resistance values from 45 to 3000 Ohm with 0.5Ohm resolution.
Datalogger (Option): The generated calibrator signal and the measured signal at the multimeter input
will be stored as tables with date and time added. The interval is selectable from 2 sec. to 24h. The
data can be transferred to a PC, shown as tables and graphics and handled under Windows and
Excel.
Transients: Eight memory slots are available for storing of fast signals at the multimeter input. Each
transient ca individually be shown at the LCD display and optional transferred to a PC, shown as
tables and graphics and handled under Windows and Excel.
M505 is powered from internal rechargeable battery which permits up to 8 hours operation.
All ranges and functions can individually be calibrated from the keypad. The Terminals are 4mm gold plated
plugs, a T/C connector is used for Thermocouple outputs.
MEATEST, s.r.o. Železna 509/3, 619 00 Brno Czech Republic
www.meatest.com
tel. +420 543 250 886, fax: +420 543 250 890