SHOT COUNTERS FOR MOLD0 pages
SLOTTED KEYS
SHOT COUNTERS FOR MOLD
V Non JIS material definition is listed on P.1359 - 1360
V Manufactured by PROGRESSIVE Corporation. Counter View is a trademark of PROGRESSIVE Corporation. PAT. PEND.
KES
KESS (Stainless steel)
KEG
KEGS (Stainless steel)
B/2
4
15
0
8 0.036
10
0
20 25 30 35 40 45 50 55 60
15 16 18 20 25 30 35 40 45 50 55 60 70 80
15
18 20 25 30 35 40 45 50 55 60 70 80
20 25 30 35 40 45 50 55 60 70 80
12
KEG
14
KEGS (Stainless steel)
30 35 40 45 50 55 60 70 80 90
0
0.043
15
16
20 25 30
0
5 0.030
6
10 12 15 16 18 20 25 30 35 40 45 50 55 60
7
10
30 35 40 45 50 55 60 70 80 90
40 45 50 55 60 70 80 90 100
12 15 16 18
35 40 45 50
0.250.40
7 0.036
55 60 70 80
90 100 110
Tolerance
B212
Inch screw
No.8 32UNC
0.400.60
*
48
10
26
0.2
0
Fixed mold plate
0.3
0.1
P.L.
PROGRESSIVE
T
A
Movable mold plate
X P.46
3
Code
Spec.
1Code
L dimension can be designated in 1mm
increments.
Full length
LC
B
2
3
4
5
6
7
8
Movable mold plate
LC range
520
630
850
850
1060
1560
1580
B
10
12
14
15
16
18
LC range
15 80
20 80
25 90
25 90
35100
35110
Part Number
U/Price
19
Quotation
MCVEX
Quotation
(①②)
max.R0.75
0.25
0
41.25
Actuator Rod
PROGRESSIVE
0000000
N
P65080
4
max.R0.75
Support plate
U/Price
Part
L
Number 0.1mm increments 19
MCVR 60.0124.0
Quotation
12.5
0.25
Movable mold plate
■Features
0.12
(Movable mold plate side chart)
■Method of specifying the L dimension
LMovable mold plate thickness Tactuator rod protrusion of 4.0mm
V Specify taking into account the tolerance of the mold plate
thickness T.
V The protruding part of the actuator rod is the stroke of the actuator
rod. If the stroke is less than 3.75mm, the counter will not work.
Conversely, if the stroke exceeds 4.25mm, the counter may be
damaged when the mold closes.
・Counting is actuated mechanically, no miscount will occur if counter is installed correctly.
E
・ ach counter has a different serial number that will be used to identify the counter with the mold. V Counters are sold in random order.
I
・D Plate for tool identification is included for M-CVPL and M-CVEX only. Apply the adhesive seal at the back of the ID Plate to the front of the counter.
■Notes
V The Counter is non-resettable mechanical.
V For mold testing purposes, the 7-digit indicator does not start from 0(a value of 9999980 will be shown).
V MCVR Counter: Ensure that the actuator rod has a stroke of 4.0mm±0.25.
Part Number
MCVPL
MCVEX
MCVR
・MCVPL・MCVEX
L
Quantity
Rate
19
1050
10%
・MCVR
3
V Stock availability depends on subsidiary. X P.45
64.2
■Quantity discount rate X P.45
1221
Shot
Counter
22.25
U/Price
19
(only ①)
T
A
0.12
0
46.75
MCVPL
L(C)
LC28
Plate thickness T
N
P65080
Part Number
Quotation
KED6
Mold
Closed
V Installation dimension shown in above figure is just for reference purpose.
V Stroke distance of the counter pin for counting function is set at 3.75mm or more.
If the stroke is less than 3.75mm, the counter will not work.
Conversely, when the stroke exceeds 4.25mm, the counter may be damaged.
X P.46
Part Number
Actuation
Block
(Movable mold plate side chart)
V Delivery days depend on subsidiary. X P.45
R S45C
P Actuator Rod
S Electroless nickel plated
1. ore the holes for the counter and actuator rod to the dimensions shown in the figure
B
below, from the rear of the movable mold plate.
2. lot an opening for the display panel of the counter to the dimensions shown in the
S
figure below.
3. nsure that the actuator rod protrudes 4.0mm above the parting line and decide L
E
dimension depending on the mold plate thickness.
S
4. crew the actuator rod into the plunger and insert the counter from the rear of the mold plate.
5.Retain the bottom of the counter with the support plate.
MCVEX (External mount type)
24
V Stock availability depends on subsidiary. X P.45
3
5
MCVR
■Mounting dimensions and method
MCVPL (Parting line mount type)
R8
B1418
28
9999980
N
P65080
R Glass-filled nylon housing
Maximum operating temperature 120℃
Quantity 19 1019 2049 50100
Rate
5%
10%
15%
T
V o be quoted on price & lead time above Max. Q'ty.
30
Actuator Rod
6
PROGRESSIVE
28
KED6
LC
Counter Pin
Serial number
■Quantity discount rate X P.45
L
Part Number
alteration
0.1
0
40 45 50 55 60 70 80 90 100 110 11 0.110
18
Alteration
38
L
8
0
9 0.090
① R Steel
P Socket Head Cap Screws M425 (2 pieces)
MCVR (Round type)
0
0.15
0
0.18
0
0.21
0
0.25
0
0.30
0
0.35
38
KES
KESS (Stainless steel)
L
0
3 0.025 0.160.25
KED
0
5
10 12 15 16 18 20 25 30 35 40 45 50
0.030
KEDS (Stainless steel)
6
C
2
10 12 15 16 18 20 25 30 35 40 45 50
① R Glass-filled nylon housing
P Socket Head Cap Screws M425 (2 pieces)
ID Plates for tool identification
Maximum operating temperature 120℃
19.05
20 25 30
Serial number
0
0.02
15
4.5
I
V D Plate design is subject to
change without prior notice.
Tolerance
20
N
P65080
7
4
15
②Actuation Block
R
S45C
SUS316
0.12
0
10
0
3 0.025 10
18
Mold Accessories
KED KES KEG
KEDS KESS KEGS
H
L
Bh9
26
6.35
PROGRESSIVE
38
6.3
JIS B13011996
V Tensile strength: 600N/mm2 or more
2
ID Plates for
tool identification
H
6.3
Type
Type
12.7
20
6.3
H
6.3
6.3
Part Number
2 Actuation Block
26
L
H
6.3
Counter Pin
47.5
24
L
25
L
25
1.6
1 Shot Counter
Bh9
B/2
Bh9
Bh9
1.6
MCVPL (Parting line mount type) only ①
MCVEX (External mount type) ①②
①Shot Counter
C
28
KED
KEDS (Stainless steel)
T
V o be quoted on price &
lead time above Max. Q'ty.
V Delivery days depend on subsidiary. X P.45
MCVPL, MCVEX:
CounterView™ Shot Counter is a registered trademark of Progressive Components International
Corporation, covered by US Patent No.5,571,539, Canadian Patent No. 2,166,237, European Patent
No. EP726129 and Others pending.
MCVR:
CounterView™ Shot Counter is a registered trademark of Progressive Components International
Corporation, covered by US Patent No.5,571,539, Canadian Patent No. 2,166,237, European Patent
No. EP726129, S.African Patent No. 2005/5337 and Asia and others pending.
1222
"