Catalogue 2016 - CaliBox 200 pressure calibrator0 pages
Mobile calibrator CaliBox 200
CaliBox 200
mobile dP calibrator
Portable differential pressure calibrator and
reference measurement instrument
This new differential pressure generator and reference instrument has been
designed for laboratories as well as for mobile use in clean rooms. Thanks to
its rechargeable battery the device can be operated up to 48 hours independent from any external power source.
At the push of a button, the generator becomes a real reference measurement
device, if required also available with accredited certificate. The internal sensor
operates with high accuracy and long term stability, which is achieved with a
combination of a high quality sensor element and a fully automated zeroing
system. This makes the instrument not just accurate but also maintenance free!
But the CaliBox 200 offers more! Its steady and stable pressure generation
allows a calibration of static membrane and dynamic mass flow sensors.
Hence this all-rounder can be used for most of the differential pressure measurement technologies. Other strengths are the mechanical and pressure robustness.
Main features:
Pres. Range:
0...200 Pa (uni-directional)
Accuracy
:
typical +/-0.15 Pa (0.08% FS)
Mobility
:
rechargeable battery 25.6V/10 Ah (48h autonomy)
Versatility
:
can be used for membrane & mass flow sensor technology
Simplicity
:
configuration by buttons & PascalTool WIN software
Generator / Measurement
CaliBox 200
Technical data:
Flexible, accurate, fast, versatile, adaptive, robust, stable, cost efficient
Dimensions:
Weight:
360 x 304 x 194 mm
approx. 7.30 kg
Meas. ranges:
Max. resolution:
Meas. accuracy:
at +20°C
0...+200 Pa
0.01 Pa
typical <= 0.15 Pa
0.08% (of full scale)
Mobile calibrator for dP sensor calibration & adjustment
This cost efficient CaliBox 200 is an universal solution suits perfectly for
every calibration professional, who wants to calibrate on site.
The CaliBox 200 is delivered inside a robust carrying case including all
accessories such as hoses, tools, PC software etc. The differential pressure is set by a precision control button and is lead via a hose to the test
specimen. During this process the pressure is always kept stable at the
same level with no need to always build up the pressure. This permits to
calibrate efficiently several specimens in series.
The robust carrying case protects the inner life of the CaliBox 200 and an
integrated valve system protects the sensor from overload pressure. In
addition the CaliBox 200 provides a scalable and adjustable analogue
output, which can be used to connect external devices such as data loggers, PC, laptops etc.
Offset-Drift :
<= 0.15 Pa / year
(automatic zero-point cal.)
Hysteresis :
typical 0.15 Pa / year
Max. overpressure: -100… 500 kPa
www.novasina.com
Applications:
on site pressure generation
on site pressure reference device
calibration laboratory instrument
(with accreditation)
on site calibrator for dP sensor calibration (range 0 to 200 Pa)
dP-catalogue 2016
Operating temp.:
Storage temp. :
0...50°C (not condensing)
-10…+60 °C
Power supply:
For more information please visit our homepage.
Doc. 005225.00
Temperature effect: <= 0.03 Pa /°C
+/- 0.015% (of full scale)
AC : 100…260 VAC
DC : LiFePo4 battery
25.6V / 10 Ah
< 3 hours
> 24…48 hours
0/2…10V (max. load 10k)
RS-232
IP 30
IP 54
Charging time :
Operation time :
Analogue Out :
Digital interface:
Protection open :
Protection close :
page 12 / 15
"