Catalogue 2016 - Datalogger series Hygro/Data/ClimaLog0 pages
Data logger line - humidity / temperature / pressure
HygroGuard 30/ClimaLog30/DataLog 30
This new data logger series excel with useful functions and high versatility. As stand-alone
devices or integrated in PC-networks the HygroGuard 30, ClimaLog 30 and DataLog 30 can
be used in various applications for climatic data measurement and recording. The high storage
capacity of 3'2 Mio data points and the AA batteries with >1 year of operation life make this
data logger system ideal for many applications. The data visualisation and device configuration
is done by the Windows software SmartGraph III which is included in the delivery.
Novasina data logging product range:
HygroGuard 30
with internal sensors for humidity and temperature
ClimaLog 30
with internal sensors for humidity, temperature and
absolute pressure sensors
DataLog 30
with no internal sensors ready for 10 signals for monitoring systems.
Data transmission is done via a UMB-Bus interface for the
..Maxx series or 2 x 4..20 mA. (e.g. 4 x StatMaxx + 2 PascalMaxx)
Features:
High data storage capacity
Large format and flexible display
USB & Ethernet interface (TCP/IP)
Connectable with external sensors via UMB bus for monitoring networks
Versatile and intuitive software for data analysis
HygroGuard 30
Model
ClimaLog 30
DataLog 30
MEASURED PARAMETERS
Temperature
Relative humidity
Absolute humidity
Dew point temp..
Barometric air pressure
Analogue inputs ( voltage / current)
X
X
X (calculated)
X (calculated)
X
X
X (calculated)
X (calculated)
X
external sensors
external sensors
external sensors
external sensors
external sensors
2xAI + 8x Bus
X
X
3'200'000
> 1 year
X
X
X
X
X
X
X
X
X
X
3'200'000
> 1 year
X
X
X
X
X
X
X
X
X
X
3'200'000
> 1 year
X
X
X
X
X
X
X
X
X (8x signal)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
FUNCTIONS - DEVICE
Power supply battery
Power supply USB
Measured data storage
Typ. battery life
LC-Display
One button operation
1-point calibration by operator
°C/°F switchable
Optical/acoustical alarm
Date / time
Records MIN/MAX/AVG
SmartGraph 3 evaluation software
UMB bus for external sensors
Data logger systems:
Dimensions
: 166x78x32 mm
Weight
: 250 g
Power supply
: 4 x LRG AA Mignon
batteries, USB
- life time > 1 year
Housing/protection : plastic ABS / IP40
Data storage
: 16 MB, 3'200'000
measured values
Interface
: USB, LAN (Ethernet)
Measurement rate : 10/30s, 1/10/12/15/30
min., 1/3/6/12/24h
Storage rate
: 1/10/12/15/30min.,
1/3/6/12/24h
Humidity measurement:
Capacitive measurement principle
Measuring range : 10...95% RH
not condensing
Accuracy
Resolution
: +/- 2.0%rh
: 0.5%rh
FUNCTIONS - SmartGraph III
Graphical representation
Numerical data table
Print function
Export function (Excel etc.)
Printouts of all measurement sites
User administration
Administration of up to 255 a loggers
Windows API interface
Applications:
HVAC installations, clean rooms, calibration and QA laboratories
Museums, archives, libraries, storage rooms
Building Management Systems and monitoring systems
Pharmaceutical- chemical-, biotechnology, food-industry
Doc. 005221.00
General catalogue AIR 2016
Temperature measurement:
NTC measurement principle
Measuring range : -20....50°C
Accuracy
: +/- 0.3°C (0...40°C)
otherwise +/- 0.5°C
Resolution
: 0.1°C
Air pressure measurement:
Measuring range : 300…1300hPa abs.
Accuracy
: +/- 0.5hPa
(700…1100hPa)
Resolution
: 0.1hPa
page 18 / 37
"