TP1_digital_e0 pages
novotechnik
nnnnSiedle Group
nnnnNOVOSTRICTIVE
nnnnTransducer
nnnnup to 4500 mm
nnnntouchless
nnnnabsolute
nnnnSeries TP1
nnnnwith Start-Stop-, SSI-,
nnnnDyMoS interface
nnnnSpecial features
nnnn• absolute transducer in
nnnnrobust profile design
nnnn• NOVOSTRICTIVE non-
nnnncontacting magnetostrictive
nnnnmeasurement principle
nnnn• non-contact position
nnnndetection
nnnn• wear-free, unlimited
nnnnmechanical life span
nnnn• Start-Stop pulse interface
nnnnwith normed speed of opera-
nnnntion 2800 m/s
nnnn• Synchronous serial interface
nnnn• DyMoS®-interface with data
nnnntransfer monitoring
nnnn• excellent linearity
nnnnup to 10 urn
nnnn• resolution up to 0.001 mm
nnnnregardless of stroke length
nnnn• low temperature coefficient
nnnn<15 ppm/K
nnnn• insensitive to shock and
nnnnvibration
nnnn• cable or connector version
nnnnavailable
nnnn• protection class IP67 / IP68
nnnnPosition transducer with
nnnnNOVOSTRICTIVE non-
nnnncontacting magnetostrictive
nnnnmeasurement principle for di-
nnnnrect, accurate measurement
nnnnof travel in display- or
nnnnfeedback applications.
nnnnThe measurement with floa-
nnnnting position marker takes
nnnnplace contactless and there-
nnnnfore wear-free.
nnnnThe passive position marker
nnnn(magnet) is optionally as floa-
nnnnting or guided design availa-
nnnnble.
nnnnThe fixing via mounting
nnnnclamps allows a very simple,
nnnnflexible mounting and a preci-
nnnnse adjustment of the installa-
nnnntion position.
nnnnThe aluminium housing was
nnnndesigned in such a way, that
nnnna closed tight construction
nnnnform with reduced installation
nnnndimensions could be realized.
nnnnThe transducer is insensitive
nnnnto soilings such as dust, hu-
nnnnmidity or oils.
nnnnThe high mechanical robust-
nnnnness of the transducer in
nnnncombination with the measu-
nnnnrement principle enables me-
nnnnasuring stroke lengths up to
nnnn4500 mm.
nnnnThe integrated advanced
nnnnASIC electronics provides an-
nnnnstandardized absolute output
nnnnsignal.
nnnnThe pulse interface allows a
nnnnfully toleranced processing of
nnnnboth edges of the Start/Stop
nnnnsignal and an usage of up to
nnnn3 position markers.
nnnnIn addition to the familiar
nnnninterfaces such as the syn-
nnnnchronous serial interface with
nnnn24, 25 or 26 bit and the
nnnnStart/Stop pulse interface al-
nnnnso a high-dynamic serial
nnnnDyMoS® interface with data
nnnntransfer monitoring is offered.
nnnnThe advantages of conventio-
nnnnnal interfaces and bus interfa-
nnnnces have been combined in
nnnnthis DyMoS® interface. In ad-
nnnndition to the position value,
nnnnthe DyMoS® interface also
nnnnallows the actual velocity va-
nnnnlue to be sent.
nnnnAdditional interfaces see
nnnnseparate data sheet.
nnnnDescription
nnnnHousing
nnnnAluminium, anodized, metal end flanges
nnnnMounting
nnnnadjustable clamps
nnnnPosition marker
nnnnMeasurement principle
nnnnElectr. connections
nnnnfloating position marker, plastic
nnnnguided position marker, ball coupling
nnnnNOVOSTRICTIVE touchless magnetostrictive
nnnn8-pin round connector, shielded, M12 x 1
nnnn8-pin round connector, shielded, IEC130-9
nnnn6-pin round connector, schielded, IEC130-9
nnnn8-wire PUR / PVC-cable, 8 x 0.25 mm',
nnnnshielded: 1 m, 5 m or 10 m length
nnnnSMD with ASIC, integrated
nnnnConnector casing resp. shield is connected with the sensor
nnnnhousing,
nnnnhousing is capacitive decoupled to the electronic
"