optris CTlaser F60 pages
optris® CTlaser F2 / F6
FEATURES
Non-contact temperature measurement
of CO2 and CO flame gases up to 1650°C
JJ
JJ
JJ
JJ
JJ
JJ
General Specifications
Environmental rating
Ambient temperature
Accurate temperature measurement of CO2 (F2) or
CO (F6) flame gases in the range of 200°C up to
1650°C in combustion processes, garbage burning
or processes inside chemical reactors
Double laser aiming marks real spot location and
spot size up from 1.6 mm at any distance
Optics 45:1 with selectable focus, compact sensor
head size
Usable up to 85°C ambient temperature without
cooling and automatic laser switch off at 50°C
Cooling and protection accessories for harsh
environmental conditions
Calibrated under inert gas atmosphere (Argon)
Measurement Specifications
IP 65 (NEMA-4)
-20°C to 85°C (sensing head,
50°C with laser ON)
0°C to 85 (electronics)
Storage temperature
600 g (sensing head)
420 g (electronics)
Optical resolution
(90 % energy)
45:1
System accuracy
(at ambient temp. 23 ± 5°C)
± 1% 1) 2)
Repeatability
(at ambient temp. 23 ± 5°C)
± 0.5% or ± 0.5°C 2)
Temperature resolution
(digital)
0.1 K
Exposure time3) (90% signal)
10 ms
Emissivity/Gain
(adjustable via programming
keys or software)
0.100 - 1.100
Transmissivity/Gain
(adjustable via programming
keys or software)
0.100 - 1.100
Signal processing
(parameter adjustable via
programming keys or software, respectively)
peak hold, valley hold, average;
extended hold function with
threshold and hysteresis
Software
optris Compact Connect
IEC 68-2-27: 50 G, 11 ms, any axis
Weight
4.24 μm (F2)
4.64 μm (F6)
IEC 68-2-6: 3 G, 11-200 Hz,
any axis
Shock (sensor)
Spectral range
10 - 95%, non condensing
Vibration (sensor)
200°C - 1450°C (F2 / F6)
400°C - 1650°C (F2H / F6H)
-40 to 85°C (sensing head)
-40°C to 85°C (electronics)
Relative humidity
Temperature range
(scalable via programming
keys or software)
Electrical Specifications
Outputs/analog
0/4 - 20 mA, 0-5/10 V, thermocouple
J, K
Output/alarm
24 V/50 mA (open collector)
Optional
relay: 2 x 60 V DC/42 V ACeff; 0.4 A;
optically isolated
Outputs/digital (optional)
USB, RS232, RS485, CAN, Profibus
DP, Ethernet
Output impedances
mA max. 500 Ω (with 5-36 V DC)
mV min. 100 kΩ load impedance
thermocouple 20 Ω
Inputs
programmable functional inputs
for external emissivity adjustment,
ambient temperature compensation,
trigger (reset of hold functions)
Cable length
max. 160 mA
Power Supply
8-36 V DC
Laser 635 nm
2)
3 m (standard), 8 m, 15 m
Current draw
for object temperatures above 300°C
ε = 1, response time 1 s
3)
with dynamic adaptation at low signal levels
1)
1 mW, ON/OFF via electronic box or
software