AQ-F Catalog0 pages
AQ-F
SSR for high-frequency
switching of industrial
equipment
AQ-F RELAYS
FEATURES
RoHS compliant
TYPICAL APPLICATIONS
1. Suitable for high-capacity and highfrequency switching
2. Same size, same terminal
arrangement as HC relay
Sockets for HC relays are applicable
3. Two load types available:
DC output type (2 A, 3 A)
AC output type (2 A, 3 A)
4. Wide range of input voltage:
3 V to 28 V
1. Drive for small-sized motor, heater,
solenoid and electromagnetic
valves.
2. NC machine
3. Printing machine
4. Machine tool
5. Robot for industrial use
6. Wrapping and packing machine
TYPES
Types
Load current
2A
3A
2A
3A
AC output
DC output
Load voltage
Input voltage
75 to 250V AC
3 to 28V DC
3 to 60V DC
Part No.
AQF2A2-ZT3/28V DC
AQF3A2-ZT3/28V DC
AQF2AD1-3/28V DC
AQF3AD1-3/28V DC
3 to 28V DC
Standard packing; Carton: 20 pcs., Case: 200 pcs.
RATING
1. Ratings (Ambient temperature: 20°C 68°F, Input voltage ripple: 1% or less)
AC output
Type
Item
Input
side
Load
side
2A
Input voltage
Input impedance
Drop-out voltage,
min.
Max. load current
Load voltage
Non-repetitive surge
current
Max. “OFF-state”
leakage current
2A
Remarks
3A
3 to 28 V DC
Approx. 1.6 kΩ
*1
0.8 V DC
3 A*2
2 A*2
2 A*2
75 to 250 V AC
3 A*2
Ta = Max. 40°C 104°F
6 A*3
AC: In one cycle at 60 Hz
DC: 1 s
3 to 60 V DC
5 A*3
80 A*3
5 mA
Max. “ON-state”
voltage drop
Min. load current
Notes: *1.
*2.
*3.
*4.
DC output
3A
AC: at 60 Hz 200 V
DC: at 60 V
1 mA
1.6 V
at max. carrying current
5 mA*
50 mA*
4
4
Refer to REFERENCE DATA “3. Input current vs. input voltage”.
Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
Refer to REFERENCE DATA “2. Non-repetitive surge current vs. carrying time”.
When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
2. Characteristics (Ambient temperature: 20°C 68°F, Input voltage ripple: 1% or less)
Type
Item
Operate time max.
Release time, max.
Insulation resistance, min.
Breakdown voltage
Vibration
resistance
Destructive
Functional
Destructive
Functional
Ambient temperature
Storage temperature
Operational method
Shock
resistance
AC output
DC output
2A
3A
2A
1/2 cycle of voltage sine wave + 1 ms
0.5 ms
1/2 cycle of voltage sine wave + 1 ms
2 ms
100 MΩ between input and output
2,000 Vrms between input and output
10 to 55 Hz double amplitude of 3 mm
10 to 55 Hz double amplitude of 3 mm
Min. 980 m/s2 {100 G}
Min. 980 m/s2 {100 G}
–30°C to +80°C –22°F to +176°F
–30°C to +100°C –22°F to +212°F
Zero-cross (Turn-ON and Turn-OFF)
Panasonic Corporation
Automation Controls Business Unit
Remarks
3A
at 500 V DC
for 1 min.
1 hour for X, Y, Z axes
10 min. for X, Y, Z axes
5 times each for X, Y, Z axes
4 times each for X, Y, Z axes
—
industrial.panasonic.com/ac/e/
ASCTB215E 201209-T1
"