HISD Side Drum Heater0 pages
Technical Datasheet
Type HISD Drum Heaters
Applications:
The HISD range of side drum heaters are a simple and effective
method of applying heat to drums. Four standard sizes are
available for drums of 25L, 50L, 105L and most common the
200L. All four sizes of side drum heaters have their own internal
insulation to aid thermal efficiency.
HISD side drum heaters are specifically designed for the melting
or reducing the viscosity of soap’s, fats, varnishes and oil based
type of products. The 200L HISD can also be used in
conjunction with the HBD base drum heater to increase product
heat up.
Construction:
l Teflon/Polyester Jacket
l 0 to 40°C or 0 to 90°C Thermostat
l Thermal Insulation
l Adjustable Quick Release Buckles
l Standard Sizes
25L, 50L, 105L, 200L
l Bespoke Sizes to Order
l 4 Metre Power Cable
l Class II Double Insulation
l IP40 Protection
Holroyd Components Ltd.
Shire Hill Industrial Estate,
Saffron Walden, Essex
CB11 3AQ United Kingdom
Tel: +44 (0) 1799 523177
Fax: +44 (0) 1799 513714
sales@holroydcomponents.com
www.holroydcomponents.com
UL and VDE approved manufacturing facilities
The heating element of the HISD range of side drum heaters is
stiched into an insulated jacket made from a water resistant,
Teflon/Polyester material, insulated with a stitched blanket of
needled silica glass complete with quick release buckles for ease
of installation and removal. The heating element is of double
insulated construction for safety.
All HISD side drum heaters are supplied with 4 metres of
rubber power cable and fitted with either a 0 to +40°C or
0 to +90°C capillary thermostat.
Jacket Material: Heated Face - Polyester base fabric. Teflon
coated. Outer face - 1100 deitex texturised
Nylon polyurethane coated
Insulation:
Glass filament blanket
Element:
Silicone insulated spiral wound resistance
element
Control:
0 to +40° or 0 to +90°C Adjustable thermostat
Power Cable:
4 Metre HO7RN-F
Fixing:
Nylon webbing with quick release
adjustable buckles
Health and Safety:
All HISD side drum heaters are manufactured to conform to the
EEC low voltage and EMC directives and CE marked accordingly.
It is advised that power to the heater jacket be disconnected when
the container is either empty or being filled, or upon installation or
removal of the heater itself. It is recommended that the unit be
operated in a dry environment with the container vented to avoid
build up of internal pressure.
www.holroydcomponents.com
"