V&A 5 1/2 Bench Multimeter VA82 Electric Instrument0 pages
5 1/2 Bench Multimeter V&A
®
INSTRUMENT
► VA82
Key Features
• 12 different measurement functions: DCV/ACV, DCI/ACI, Q2W/Q4W,
frequency/period, diode test, continuity, dB/dBm, etc.
• High-brightness vacuum fluorescent display (VFD)
•True-rms AC voltage and current measurement, with high
frequency of 100kHz
• Maximum reading of 120,000 digits
• DCV measurement accuracy up to 0.01 %, resolution 1 uV
Maximum measurement rate:45times/second
• Equal accuracy frequency measurement more than 1 MHz,
minimum resolution of 10uHz
•Zeroing (RFL) mode to eliminate residual reading
• 2W and 4W resistance measurement modes selectable
• Built-in mathematics calculation functions: mX+b,%,dB, dBm
•512 readings storage and MAX/MIN/AVER/STD statistics
• HI/IN/LO comparator function
•GPIB and RS-232 interfaces for convenient system communication
Calibration performed without opening the cover
• 10 sets of measurement states saved and recalled up
Specifications
Full-scale reading & reading rate (readings/second)
Speed_| Slow I Medium
Full-scale reading (digits)
Reading
rate
(readings/
second)
DCV
DCV.DCI
ACV.ACI
0-2W
Q-4W
Fast
119,999
119,999
11,999
3.5
13
45
22
3.5
2.7
13
10
45
32.9
Range
lOOmV
IV
10V
100V
Max. reading
119.999
1.19999
11.9999
119.999
1000V 1010.00
Resolution
luV
10uV
100uV
ImV
lOmV
Accuracy (1 year)
0.02%+8
0.01 %+4
0.01 %+4
0.01 %+4
0.01 %+4
Input impedance
>10GO
>10GD
>10GQ
10MO
10MO
DCL
Range
10mA
100mA
1A
10A
Max. reading
11.9999
119.999
1.19999
11.9999
Resolution
0.1 uA
1uA
10uA
IOOUA
Accuracy (1 year)
0.05%+8
0.05%+4
0.10%+4
0.15%+4
Load voltage/shunt resistance
<0.15V/10O
<i.5v/ion
<0.3V/0.1Q
<0.15V/ lOmO
AC voltage (ACV true-rms measurement)
Range | lOOmV | 1V | 10V | 100V | 750V |
Max. reading | 119.999 | 1.19999 | 11.9999 | 119.999 | 757.5 |
Resolution | 1uV | 10uV | 100uV | 1mV | 10mV |
Accuracy (year) | 10-20 Hz | 1.5%+100 | |||
20-50 Hz | 0.5%+100 | ||||
50-20 kHz | 0.1%+100 | ||||
20-50 kHz | 0.3%+150 | 0.3%+100 | |||
50-100 kHz | 1%+150 | 1%+100 |
AC voltage (ACV true-rms measurement) | |||||||||
Range | 10mA | 1A | 10A | ||||||
Max. reading | 11.9999 | 1.19999 | 11.9999 | ||||||
Resolution | 0.1 uA | lOp A | IOOUA | ||||||
Accuracy (year) | 10-20 Hz | 1%+80 | |||||||
20-50 Hz | 0.5%+80 | ||||||||
50~2kHz | 0.25%+80 | ||||||||
2-10 kHz | 2%+80 | ||||||||
Load voltage/shunt resistance | <0.15V/10O | <0.3V/0.1fi | <0.15V/10mQ | ||||||
Resistance (Q2W/Q4W) | |||||||||
Range | Max. reading | Resolution | Measurement current | Accuracy (1 year) | |||||
100.000 Q | 119.999 | 1mQ | 1 mA | 0.05%+8 | |||||
1.00000 kO | 1.19999 | lOmO | 1 mA | 0.03%+4 | |||||
10.0000 kO | 11.9999 | lOOmfi | IOOuA | 0.03%+4 | |||||
100.000 kO | 119.999 | 1 Q | IOuA | 0.03%+4 | |||||
i.ooooo MQ | 1.19999 | 10Q | IOuA | 0.03%+4 | |||||
10.0000 MQ | 11.9999 | 100Q | 7.0*Rx/(10M+Rx) | 0.10%+4 | |||||
100.000 MCI | 119.999 | 1 kD | 7.0»Rx/(10M+Rx) | 0.50%+8 | |||||
Frequency | |||||||||
Range | Max. reading | Resolution | Accuracy (1 year) | Sensitivity (sine wave) | |||||
5-10 Hz | 9.99999 | 10|jHz | 0.050%+100 | 200mV rms | |||||
10-IOOHz | 99.9999 | IOOUHZ | 0.010%+10 | 40mV rms | |||||
100-100 kHz | 99.9999 | 0.1Hz | 0.005%+2 | 40mV rms | |||||
100k~1MHz | 999.999 | 1Hz | 0.005%+2 | lOOmV rms |
More information online at www.mastech.com.cn
"