CLAMPS0 pages
Pneumatic power clamps
nnnnUNIVERSAL series
nnnnUNIVERS.p.A.
nnnnHeadquarter
nnnn20128 Milano
nnnnVia Eraclito, 31
nnnnTel.+39 02 25298.1
nnnnFax+39 02 2575254
nnnninfo@univer-group.com
nnnnwww.univer-group.com
nnnnThe handling, positioning as well as the maintenance operations have to be carried out by observing all conditions which guarantee the
nnnnsecurity of the staff and only by authorized personnel.The residual risks regarding the sole maintenance phase consist in the squashing
nnnnof the upper parts of the operator's body between the clamping arm and the shims mounted under the arm. As a preventive measure
nnnnan appropriate signalling or an adequate security system placed near the dangerous areas and which have to be installed by the user
nnnnwill alert the operator.
nnnn> Opening angle adjustment
nnnn1. Set the clamping arm in the open position and supply the sensor
nnnn2. Slide the cover to access the angle adjustment
nnnn3. Insert the hex key until it has engaged with the screw
nnnn4. Keep the key pushed in its site and rotate it clockwisely to increase the opening angle or counter
nnnnclockwisely to reduce the opening angle
nnnn5. Close the cover
nnnn> Clamping arm mounting
nnnnirately t
nnnnTighten moderately the fixing screws; then tighten completely the corresponding pairs of screws, one on the right and the other on the left
nnnnclamping arm.
nnnnClamping arm
nnnnFixing bosses^
nnnn\
nnnnYES
nnnnDo not insert the dowels in the clamping arm when it is
nnnnassembled on the clamp
nnnnScrew | Tightening torque |
M5 | 14Nm |
M6 | 18Nm |
M8 | 30 Nm |
M10 | 35 Nm |
> Fixing instructions
nnnnThe fixing of the unit to the equipment can be carried out by using the front, rear or side part of the housing of the clamp.
nnnnI Fixing to the front or rear surface
nnnnInsert two hardened and grinded pins into the special seats such as to locate the clamp to the tooling:
nnnnSeries | 0 dowels |
UB_40 | 6 |
UB_50and UB_63 | 8 |
UB_80 | 8 |