HEAVY DUTY PUMPS, SERIES 41950 pages
VIKING® HEAVY DUTY PUMPS
Section
Page
144.1
Issue
SERIES 4195
STANDARD CONSTRUCTION
144
H
FEATURES
① Pressure
Range
250 PSI (17 BAR) for 100 SSU (20 cSt) and above
150 PSI (10 BAR) for 38 to 100 SSU (3 cSt to 20 cSt)
100 PSI (7 BAR) for below 38 SSU (3 cSt)
① Temperature
Range
- 40° F. to + 350°F. (- 40° C. to + 177°C.)
① Viscosity
Range
28 SSU to 15,000 SSU
(0.1 cP to 3,300 cSt)
SERIES 4195 Pumps
Cutaway View
“AS”, “AK”, “AL”
SERIES 4195 Pumps
Cutaway View
“G”, “GG”, “H”, “HJ”, “HL”
GPM up to 75
(M³/Hr up to 17)
② (Nominal Rating)
BALL BEARINGS
(Standard Equipment)
Pumps are equipped with inner cas
ing ball bearing installed outside of
mechanical seal and a radial thrust
ball bearing permitting heavy-duty
service up to 250 PSI (17 BAR).
Bearings are “Sealed for Life”.
PRESSURE LUBRICATION
(Standard Equipment)
(“AS”, “AK”, “AL” Sizes)
A patented pressure lubrication
system automatically lubricates the
idler bushing. This system provides
a constant film of liquid between the
idler bushing and idler pin at a pressure equal to the pump discharge
pressure regardless of pump rotation.
DUCTILE IRON PARTS
(Standard Equipment)
(“AS”, “AK”, “AL” Sizes)
Internal pumping gears (rotor and
idler) are constructed of ductile iron
for added strength in handling all
types of liquids up to 15,000 SSU
(3,300 cSt). “HL” size rotor also
furnished in ductile iron.
O-RING GASKETS
(Standard Equipment)
O-Ring gaskets are used between
casing and head plate and between
casing and relief valve or valve
plates. Flat valve gaskets furnished
on “G”, “GG”, “H”, “HJ” and “HL”
size pumps. These gaskets provide
a positive seal eliminating a chance
for leakage at these points.
Viking’s high-speed, heavy-duty Series 4195 pumps
are available in capacities up to 75 GPM. These pumps
can be furnished directly connected to a 50 Hz or 60 Hz
motor. (See Series 4195D units shown on page 144.3.)
All eight sizes of Viking Series 4195 pumps are furnished
with single mechanical seals. This seal is a simple selfadjusting, non-leak method of shaft sealing located
ahead of the casing ball bearing. The Series 4195
pumps are built for coninuous or intermittent duty for
t
such applications as filtering, circulating, transferring,
or booster service in general industrial, petroleum and
marine uses. NOTE: “UL” listed pumps for handling LPGas require special construction. Externals are high
strength cast iron. (Ductile Iron Casing on “AS”, “AK”
and “AL” sizes). See Catalog Section 440 for details and
pricing information. Model numbers for these pumps
must be designated by a suffix -G, eg. GG4195-G or
when used with a “D” drive, GG4195D-G. “UL” listed
models must be equipped with a return-to-tank pressure
relief valve. Maximum discharge pressure for “UL” listed
models is 125 PSIG.
① Values shown represent minimums or maximums. Some special construcion or
t
consideration may be required before a cataloged pump can be ap lied to an
p
application involving maximum pressure or minimum or maxmum temperature
i
and/or viscosity. Certain models have restrictions in pressures and/or viscosities.
See specifications, page 144.2, and perform nce curves, which can be
a
electronically generated with the Viking Pump Selector Program, located on
www.vikingpump.com/pumpselector.
② Nominal capacities based on handling thin liquids.
Metric conversions are based on US measurements and rounded to the nearest
whole number.
VIKING PUMP • A Unit of IDEX Corporation • Cedar Falls, IA
©2013
"