FLOW CONTROL AND RELIEF VALVES0 pages
Pub. EC-0302
FLOW CONTROL AND RELIEF VALVES
FBG-03/06/10 (3/8, 3/4, 1-1/4)
Sub-plate Mounting
FLOW
CONTROLS
Model Number Designation / Specifications
Up to 25 MPa (3630 PSI), 500 L/min (132 U.S.GPM)
These valves are flow control valves having the functions of metre-in type flow control and pressure control.
Inlet pressure is always maintained 0.6 MPa (87 PSI) higher than the load pressure.
In a conventional flow control method, power consumption is wasteful since the pump pressure goes up to the preset
system pressure regardless of the load pressure. While, the power saving valves control the pump pressure by maintaining
a differential pressure as little as 0.6 MPa (87 PSI) against the load pressure, thereby, the power can be remarkably saved.
Moreover, with lthe temperature compensator, a stable flow control can be made regardless of oil temperature.
Setting and repeat setting of flow can be made easily with an adjustment knob having digital scales.
Graphic Symbol
Specifications
Model Numbers
FBG-03-125
Rated Flow
L /min (U.S.GPM)
Metred Flow Range
L /min (U.S.GPM)
Pressure Adjustment Range
25 (3630)
25 (3630)
250 (66)
500 (132)
1-125 (.26-33)
MPa (PSI)
FBG-10-500
125 (33)
Max. Operating Pressure
FBG-06-250
25 (3630)
Description
3-250 (.79-66)
5-500 (1.3-132)
-25 ( -3630)
MPa (PSI)
∗
-25 ( -3630)
∗
-25 ( -3630)
∗
Min. Pressure Difference Required between Inlet
0.6 (87)
0.7 (102)
0.9 (131)
1.5 (.40)
2.4 (.63)
3.5 (.92)
0.5 (73)
0.5 (73)
0.5 (73)
13.3 (29.3)
and Outlet Ports
27.3 (60.2)
57.3 (126)
MPa (PSI)
Pilot Drain Flow
L /min (U.S.GPM)
Max. Drain Line and Tank Line
Back Pressure
MPa (PSI)
Approx. Mass
kg (lbs.)
∗ See the "Min. Adjustment Pressure" for the item marked
.
Model Number Designation
FSpecial Seals
F:
Special Seals for
Phosphate Ester
Type Fluids
(Omit if not
required)
FB
G
-03
-125
-10
∗
Series Number
Type of
Mounting
Valve
Size
Max. Metred Flow
L /min (U.S.GPM)
Design
Number
Design
Standards
03
125 : 125 (33)
10
06
250 : 250 (66)
10
10
500 : 500 (132)
10
FB:
Flow Control
and Relief
Valves
G:
Sub-plate
Mounting
1. Design Standards :
Japanese Standard "JIS" and European Design Standard
None .
90 ............... N. American Design Standard
.
...............
Refer to
1
No.1
D
"