تماس با ما
وب سایت در حال به روز رسانی است. از شکیبایی شما سپاسگزار هستیم.

منابع یابی و خرید تجهیزات صنعتی

محصولات
محصولات
سازندگان
کاتالوگ
فیلم

 (ویژه صنایع و کارخانجات )

خدمات خرید ، حمل ، ثبت  سفارش ، ترخیص و تحویل هر گونه کالای صنعتی از اروپا ، چین ، ترکیه  و امارات متحده عربی
لطفا جهت خرید ، حمل ، ترخیص و تحویل هر گونه کالای صنعتی در هر نقطه از دنیا با ما در تماس باشید .
ایمیل sales@meshgad.com
تلفن تماس 41995-021

  • 1
  • 2
  • 3
  • 4
  • 6
LOADING

RVL Series Vortex Flowmeters0 pages

نسخه متنی
"

CLARK SOLUTIONS RVL Vortex Flowmeters Technical Bulletin: Application, Design, Installation INTRODUCTION Slection of the best flow meter for your spcifie application is a critical step, one that will affect the quality of your process for years. Choosing the wrong meter can lead to inaccurate readings, high mainte驭nance costs, and expensive downtime. The following section is designed to explain the technology of vortex flow meters and the specifications of the Clark Solutions vortex product line. Our goal is to ensure that the vortex meter you select meets the requirements of your specific application. HOW VORTEX FLOW METERS WORK The operation of the RVL vortex flow meter is based on the vortex shedding principle. As fluid moves around a body, vortices (eddies) are formed and move downstream. They form alternately, from one side to the other, causing pressure fluctuations. These are sensed by a piezoelectric crystal in the sensor tube, and are converted to a 4-20 mA or pulse signal. The frequency of the vortices is directly proportional to the flow. This results in extremely accurate and repeatable measurements with no troublesome moving parts. MATERIAL SELECTION When choosing the best pipe material for your process, it is necessary to review the fluid to be trans-ported, its concentration, the minimum and maximum operating temperatures, and the pressures to be accommodated. Choosing a flow meter is a similar process, but it is necessary to review a few additional considerations, such as fluid viscosity, suspended parti-cles, density of the fluid and, most importantly, expected flow range. One advantage of utilizing a Universal vortex flow meter is that there are no gas-kets or elastomers in the meter. Therefore, you only need to be concerned with the thermoplastic material used for the body construction. In a thermoplastic piping system, the material chosen for the flow meter should match that of the pipe if at all possible. If you are planning to install a meter in a metal pipe system, you must consider three operating conditions: temͭperature, media, and pressure. Chemical resistance data is available on request from Clark. FLOW RATE AND RANGE REQUIREMENTS When choosing a flow meter, it is necessary to verify with the supplier that the unit selected is suited for your specific flow range needs. Most manufacturers state flow range capabilities by publishing maximum allowed flow rates. Then they provide a turndown ratio to determine minimum flow rate. To use the turndown ratio, simply divide the maximum rate by the ratio to determine the minimum rate. RVL vortex flow meters offered by Clark have a 12:1 turndown ratio (exceptions: RVL025 1/4" unit and RVL050L 1/2" unit; 8:1). LINE FLUIDS Many factors may affect the capability of a meter to accurately measure the flow of specific fluids. Different solutions have varying effects on meters. For instance, heavy particle suspension will wear down internal parts on some meters or cause sensing inaccuracies for non-obtrusive metering systems. For vortex flow meters, high viscosities tend to dampen the formation of vortices and reduce the effective range. Particles and internal bubbles do not usually affect vortex meters. PVDF models work very well in slurry services. However, slurries containing grit will wear down the bluff body, although it can withstand a 5% reduction before accuracy is affected. Also, long fibers will catch and build up on the bluff, decreasing accuracy. Stanͭdard factory calibration is for 32 SSU (1 CST) viscos-ity liquid. Viscosity above 1 CST will raise the minimum readable flow rate, reducing rangeability. The effect is linear to viscosity. No adjustments are required for specific gravities up to 2.0. Liquids with high specific gravities will adversely affect the permissible amount and duration of overrange flow. The following chart indicates the reduction of range based on viscosity. Viscosity Min. Max. Flow Range 1 CST 1 12 12:1 2 CST 2 12 6:1 3 CST 3 12 4:1 4 CST 4 12 3:1 5 CST 5 12 2.4:1 6 CST 6 12 2:1 E. Clark & Associates 10 Brent Drive Օ Hudson, MA 01749 Tel. 978 / 568 3400 Օ Fax 978 / 568 0060

"

IRAN INDUSTRY EXPO

The largest online Industrial exhibition in Iran

 عضویت ورود   ENGLISH


اگر مجموعه شما جزو صنایع مادر و معظم در فیلد پالایشگاه ، پتروشیمی ، حفاری ، نیروگاه ، معادن و فلزات ، خودروسازی ، تولید مواد غذایی و.... می باشد لطفا درخواست خود را بر روی سربرگ به فاکس 88206264 و یا ایمیل enquiry@iranindustryexpo.com بنام شرکت مهندسی و بازرگانی مشگاد ارسال فرمایید.
اگر مجموعه شما جزو بنگاه های متوسط و کوچک در فیلد تولید ، بازرگانی ، مشاوره ، پیمانکاری ، دانشگاه ، پژوهشگاه ، توزیع ، فروشگاهی وکارگاهی می باشد ، پس از عضویت و با پرداخت هزینه ( به ازای هر درخواست معادل 50 یورو ) از خدمات زیر برخوردار خواهید شد :
  • پاسخ به پرسش های فنی و دریافت مشاوره از سازنده ، دریافت کاتالوگ و اطلاعات تکمیلی
  • دريافت پرفورما از شرکت سازنده
  • اطلاع از زمان تحويل و قيمت خالص كالا
  • اطلاع از هزينه هاي حمل و ترخيص و کارمزد تا تحويل كالا به انبار شما در هر نقطه از كشور
  • دریافت پیش فاکتوررسمی ( ارزی و یا ریالی ) به روش کارمزدی
*صدور پیش فاکتور رسمی فقط به نام شرکتهای ثبت شده که دارای کد بازرگانی معتبر باشند انجام پذیر است. در صورتیکه در حین مکاتبه با شرکت سازنده مشخص شود که دارای نماینده انحصاری و یا شعبه در ایران بوده و یا به به هر دلیل شرکت سازنده از فروش کالا به بازار ایران استنکاف نماید ارایه این سرویس متوقف و وجه دریافتی به حساب کاربر عودت می شود

ادامه