ELADOS ® EMP-KKS0 pages
Electric motor-driven
diphragm-type
metering pump
with pre-delivery
ELADOS® EMP-KKS
for dosing capacity
0,2 - 1,4 l/h
• High metering precision even with degassing products
• Smallest possible metered quantity
• High level of reproducibility
• Many electronical control options
• Self-priming and venting even with small metering quantities
General
ELADOS EMP-KKS diphragm-type-metering pumps are efficient precision-metering
units for chemicals which have tendency to degas. On the basis of technical unit with a predelivery diaphragm and a sealless ceramic-piston-cylinder unit, the smallest possible metered
quantity is achieved with high reproducibility - with the maximum number of strokes. Like the
ELADOS EMP diaphragm-metering pump range, they can be adjusted to any operational
requirements on the basis of a variety of control options for quantitative and proportional metering.
E 10
On / off switch, mechanical stroke adjustment
• Standard signal mode (actuation via external standard signal
0/4-20mA or 20-0/4mA)
E 11
As E 10, additional empty signal input with level pre-warning,
empty signal output
E 60
•
Mechanical stroke adjustment
• Charge mode (a previously selected quantity is metered,
with initiation via an external initiation
pulse)
•
Back-lit graphic display, 4 operating keys
• Single stroke control (each stroke is completely executed)
• Metering monitoring via stroke-signal output or via external metering-monitoring system
(e.g. liquid level switch) possible
• Registration of operating and consumption data
(calculative)
•
Calibration function
Selectable operating modes:
•
Standard signal
•
Enable
Outputs:
• Level monitoring package vessel
Stroke signal
Malfunction
E 60PLUS as E 60, but additional with dongle box (add-on unit for consumption data acquisition)
Strokes/min
Percent
•
Pulse
•
Selection of metering rate/metering frequency via:
•
•
•
Internal mode
•
Inputs:
• Level monitoring, package vessel (reserve and empty signal)
Liter/h (or gallon/h)
External mode
• Pulse mode (actuation via pulses)
- Pulse multiplication (one incoming pulse = n metering
strokes)
- Pulse division (n incoming pulses = 1 metering stroke)
• Display of real metering quantity/time and automatic readjustment of pump output (only in
combination with external flow monitoring system, e.g. oval
gear meter)
•
Automatic calibration function via oval gear meter
•
Consumption data control by means of oval gear meter
Dosing devices for aggressive gases and fluids / Dosing devices for fluids / Electric motor-driven diaphragm pumps