1 OPERATION/FUNCTION
0 - off
Provide a new septum on your
sample bottle. Insert the bottle,
with cap and septum into the
bottom part of the bayonet
sleeve.
Connect the bottom part of the
bayonet sleeve to the upperpart,
move the bottom part upwards
and lock it by turning it in the
slot in the top end position.
1 - back purge
Turn the handle to the “back
purge” position, allowing a flow
of purge gas through the sampler
to the process to ensure representative sampling. This position can
be held for any required time.
2 - sample
Turn the handle to the “sample”
position, allowing the vacuum to
be connected to the vent outlet
of the needle assembly to create
an under pressure in the sample
bottle. The product flows into the
sample bottle.
When the required amount has
been taken, turn the handle into
the “off” position.