MicroTSCM Streaming Current Monitor0 pages
ft
nnnnWater Quality Measurement Solutions
nnnnA Watts Water Technologies Company
nnnnMicro ISCM Streaming Current Monitor
nnnnThe M icro I SCM establishes a new level of control for plant operators that depend upon Streaming
nnnnCurrent to maintain water quality. Unlike other systems, the instrument can be calibrated to a known
nnnnIon Charge unit (ICu) value, using a cationic polymer solution. Once calibrated, the operator can use
nnnnthe M icro I SCM to determine the control set-point for the plant. This set-point is established through
nnnnoptimization and it reflects the actual ICu of the sample stream.
nnnnStandard Features
nnnn• Graphical Display
nnnnQuickly view historical trending of ICu readings over an 8 or 24 hour period.
nnnn• Calibration to a Known Value
nnnnMaintains accuracy over the life of the probe.
nnnn• Built-in Diagnostics
nnnnFull time diagnostic software automatically monitors and detects errors.
nnnn• On-Screen Instructions
nnnnEasy to use menus guide the operator through set-up and calibration
nnnnprocedures.
nnnn• User Programmable Offset
nnnnSimplify human interface by setting the output to reflect zero when optimum
nnnndosing conditions are met.
nnnn• Three Separate Alarm Contacts
nnnnSystem alarm and two user-programmable Hi/Low ICu alarms provide
nnnncontinuous confidence in the measuring process.
nnnn• High / Low Gain Switch
nnnnOptional Features
nnnn• Flow Alarm
nnnnAutomatically alerts the operator if there is a disruption in flow to the sensor.
nnnn• Proportional Integral Controller
nnnnAutomatically controls coagulant dosing.
nnnn• Serial Ports _
nnnnThe optional RS-232 or RS-485 serial ports allow the Micro I SCM to easily
nnnnadapt to a digital environment.
nnnnOrdering Information
nnnnCat. No. Description
nnnn19549 | M icro I SCM 1,115V/240VAC, 50/60 Hz |
19950 | Micro I SCM II, with built-in PI Controller |
19553 | Micro I SCM III, with built-in PI Controller and RS-232 |
19554 | Micro I SCM IV, with built-in PI Controller and RS-485 |
All models include 25ft. of interconnecting cable and Calibration Kit.
nnnnAccessories
nnnn19886L | Flow/Level Alarm, provides a remote alarm for inadequate sample flow |
19922 | Calibration Kit |
19986 | NEMA 4X Housing for outdoor installation of monitor |
19994 | Spare Cell and Probe set |
Specifications
nnnnRange: | ± 10 ICu (SCU) |
Resolution: | 0.01 ICu (SCU) |
Accuracy: | ± 0.1% of full scale |
Response Time: | 1 Second |
Alarms: | 2 Settable Hi/Low/Off 1 System Alarm 1 Flow Alarm (requires optional hardware) |
Average Time: | User Selectable |
Analog Output: | 4-20 mA Oto 10 VDC |
Digital Outputs: (Optional) | RS-232 Serial RS-485 Serial |
Display: | Graphical Trending and Numeric |
Sensor Probe:: | Submersible to a depth of 120mm 6 to 10 liters per minute flow rate required |
Wetted Materials: | HPDE, PTFE, Stainless Steel, Neoprene.ABS |
Specifications subject to change without notice.
nnnn3170 Metro Parkway, Ft. Myers FL 33916 e-mail: hfinfo@watts.com
nnnnph: (239)-337-2116 • fax: (239) 332-7643 • toll free: 888-203-7248 www.hfscientific.com
nnnn8-04-2010 Rev 1
"