P-14 Capacitive Humidity Sensorr0 pages
P-14
Capacitive Humidity Sensor
1/2
Product
The P-14 humidity sensor was specially developed to satisfy the wide range of applications in HVAC, tests and
measurement, white goods and industrial field. By the consistent use of state-of-the-art production technologies
and our extensive know-how in the field of high performance polymers, we have succeeded in producing a high
quality sensor with an almost linear characteristic. The possibility of selecting the electrical connections provides
users with ideal opportunities for implementing their own sensor design without limitation.
Advantages
High humidity stability
Low drift
Condensation resistant – fast recovering time after dewing,
and at high dew point temperatures as well
High chemical resistance
Wide temperature operating range
Various wired solutions available
Technical Data
Wired
Humidity Operating Range:
Operating Temperature Range:
Capacitance (C30)
(at 23 °C and 30% RH):
Sensitivity (15 ... 90% RH):
Loss Factor (at 23 °C, at 10 kHz,
at 90% RH):
Linearity Error (15 ... 90% RH
at 23 °C, after one-point
calibration):
Hysteresis: 1 h, 20% RH bei 23 °C
1 h, 85% RH bei 70 °C
1 h, 20% RH bei 23 °C
Response Time t63
(50% RH
0% RH) at 23 °C:
Frequency Range:
Maximum Operating Voltage:
Signal Form:
Connectors:
SMD
0 ... 100% RH
-50 ... +150 °C
150 pF ± 50 pF
0 ... 100% RH
-50 ... +150 °C
180 pF ± 50 pF
0.25 pF / % RH (at C30 = 150 pF)
< 0.01
0.30 pF / % RH (at C30 = 180 pF)
< 0.01
< 1.5% RH
< 1.5% RH
< 1.5% RH
< 1.5% RH
<5s
<5s
1 ... 100 kHz (recommended 10 kHz) 1 ... 100 kHz (recommended 10 kHz)
< 12 Vpp AC
< 12 Vpp AC
alternating signal without DC bias
alternating signal without DC bias
Wires or customer specific
SMD