T24-SAf0 pages
T24-SAf (i & e)
New Generation Telemetry Fast Strain Gauge Acquisition Module
Features
2KHz data acquisition
Very small size – 18 x 40 x 7mm including signal conditioning module
Worldwide licence exempt 2.4 GHz radio
2 way radio system for data integrity
Remote power on/off (sleep/wake)
120 metre (400 feet) range maximum
Simple configuration and calibrated via PC using base station with Telemetry
Toolkit software provided
Internal or external antenna options
Introduction
For high speed application provides measurements at 2KHz with 200 packets per
second containing 10 x 32 bit values representing nano volts/volt. The T24-SA is
a high performance strain gauge to radio telemetry converter module, offering
precision measurement with high performance two-way telemetry.
Usable around the globe on licence-free 2.4GHz frequency, the T24 range
avoids local radio interference to ensure data integrity and security. For use in
any measuring applications, from torque to weight, vibration to flow, the T24
offers users a complete solution to your measurement requirements.
The modules form part of a simple measurement system that offers the opportunity to
collect measurements from a variety of sources, enabling accurate and immediate
data collection without the requirement for extensive and labour intensive cabling
operations.
The wide temperature operating range and the robust technology ensures that the
module it is not susceptible to harsh physical or electrical environments.
Options include internal or external antenna.
Specifications
General Radio
Min
Typical
Licence
Max
Units
Licence Exempt
Modulation method
MS (QPSK)
Radio type
Transceiver (2 way)
Data rate
250
Radio Frequency
K bits/sec
2.4000
2.4835
GHz
Range RAD24i (Integrated antenna)
60 (200)
Metres (feet)
Range RAD24e (External antenna)
100 (325)
Metres (feet)
Max
Units
Power
1
Channels (DSSS)
mw
16
T24-SAf
Specification with 1000R bridge, 2.5mV/V, at 3V supply at 25 Deg C
Measurement
Min
Typical
Strain Gauge Excitation System
Strain Gauge Excitation Voltage
Strain Gauge Drive Capability
4 Wire
4. 5
5
5.25
VDC
85
-
5000
Ohms
3.2
+/-mV/V
ppm/C
Maximum Gauge Sensitivity (FR)
Offset Temperature Stability
1
4
Gain Temperature Stability
3
5
ppm/C
Offset Stability with Time
20
80
ppm of FR (1)
30
ppm of FR (2)
5
25
ppm of FR
Gain Stability with Time
Non Linearity before Linearization
Internal Resolution
16,000,000/ 24
Resolution/Bits
Noise free resolution is 8000/13 Bytes 10 second sample
Electrical
Min
Typical
Max
Power Supply voltage
2.1
3.0
3.6
V dc
50
mV ac pk-pk
Power Supply ripple
Units
"