Infrared CelsiMeter® CMI-056V0 pages
IR- CelsiMeter® new model CMI-056V
Nonecontact Digital-Thermometer
with Optimal Price- / Performance- and Quality Ratio
Principle of nonecontact measurement
All object surfaces emit in all directions a linear temperature dependant heat radiation. That's sort of like
sensation felt either comfortable or stinging when
moving one's palm without touching towards a more
or less heated surface.
This heat energy radiation also depends on the surface condition of the emitting surface. A dull black
surface is a good and effective emitter, glossy and
shiny metallic surfaces have less radiation efficiency. This physical behavior is termed as emission or
emissivity factor and describes the surface thermal
characteristic. The opposite is the absorption factor
for heat radiation. A black painted car heats up
quicker and higher than a white painted car.
Fabrics, woods, concrete, stone, skin, plants or other none-metallic surfaces all have an emissivity between 0,90 .. 0,98. The IR-CelsiMeter® CMI-056V
features an adjustable emissivity factor, adjustable
from 0.10 to 1.00.
Shiny, none-oxidized or polished metallic surfaces
have a much lower emissivity factor. Correction tables can be created.
Design of nonecontact measurement gear
Todays advanced technologies in electronics, sensors, chips and microprocessors, LED's, LCD-displays, but also of plastic processing (lenses, reflectors,..) permit almost any measurement applications.
The IR sensor in the IR-CelsiMeter, the radiation
eye, can pick up within a small viewing angle the radiation from a surface, almost like a binocular selects the view of a remote scenery. The "IR blind"
operator uses the internal laser target marker (see
picture) to view the area which sends the radiation
and of which the surface temperature is to be taken.
On a measuring distance of 1 meter the measuring
spot has a diameter of 80 mm, a ratio of about 1:12.
TP2CMI056V_16658-OP
P1/2 print: 5.3.2010
Point & Click ...
the use of an IR-CelsiMeter®
as a thermometer could not be easier.
With the pistol like trigger continuously pulled there
will be a measurement cycle displayed every 0,5
seconds. The last value taken will be on HOLD on
display for 5 seconds before the CelsiMeter® automatically shuts down for battery energy conservation. A new triggered cycle will be started and displayed within 0,8 seconds.
IR-CelsiMeter® Model CMI-056V
Range
Resolution
Repeatability
Accuracy
ambient @ +25°C
Distance / spot
EM-factor
IR-wavelength
Cycle time
Sampling
LED-display
Laser marker
Activation
Ambient
Battery
Dimensions
Weight
Shipping
part #16658
-30 °C ... +530 °C
(-25 °F ... +990 °F)
°C / °F switchable
0,1 °C of display
± 1 °C
± 3 °C ( -30 ... - 15°C)
worst case
± 2 °C ( -15 ... +110°C)
worst case
± 2 % (+ 110 ... +530°C)
worst case
12 : 1
spot ø 80 mm on 1 meter
adjustable, 0.10 to 1.00
5 ... 13 µm processed
continuous sampling / HOLD of last value
0,5 second
4-digit, 23 x 27 mm, back illumination
intensive, bundled red spot, switchable
pistol like grip with pull trigger,
deactivates after approx 5 seconds
0 ... +50 °C / 10 - 90 %rH
9 Volt / MN1604 / 6LR61
185 x 95 x 46 mm
230 gramm
CelsiMeter®, Battery, Carry bag,
User manual
Point & Order!
The promotion price is time limited.
SPIRIG
S W I T Z E R L A N D
manufactured for and distributed by:
Spirig Ernest Dipl.-Ing. Postfach 1140 CH-8640 Rapperswil Schweiz
Tf: (+41) 55 222 6900 Fax:(+41) 55 222 6969
E-mail: info@spirig.com http://www.spirig.com