VI5180 pages
Via Assunta, 57 - 20834 Nova Milanese (MB) - ITALY
Tel. +39 0362 366126 Fax +39 0362 366876 www.givimisure.it sales@givimisure.it
Code
Project
Release
ST02
A31-B
A
TECHNICAL DATASHEET
DIGITAL READOUT VISION VI518
GENERAL FEATURES
Compact-design, single-axis digital readout.
Suitable for several machine tools, such as those performing cutting or
machining at a preset size, polishing, bending, grinding or straightening.
Applicable on various industries, such as wood, sheet metal, marble, rubber,
textile and automation.
Absolute (SSI protocol) or incremental encoder input signals.
Up to 8 digits displayed, including floating decimal point and negative sign.
Device diagnostic.
Internal rewritable memory.
Absolute signals RS-422: Clock, Clock , Data, Data .
Resolutions up to 0.5 μm.
Correction factor, angular reading, programmable relay outputs and many
other functions available.
Serial output RS-232, for the transmission of positions.
Panel mountable version available.
MECHANICAL AND ELECTRICAL CHARACTERISTICS
Model
VISION VI518
1 display - 1 input
Display
8 high-efficiency digits
h = 13 mm
Incremental encoder input signals
2 square waves with phase displacement of 90° ± 5° and zero reference
5 Vdc or 12 Vdc (TERMINAL BOARD)
250 mAMAX
Maximum input frequency
250 kHzMAX
Absolute (SSI) encoder input signals
RS-422 – Clock, Clock , Data, Data
Power supply
230 Vac ± 10% - 50/60 Hz / 110 Vac ± 10% - 60 Hz / 24 Vac ± 10% - 50/60 Hz
Current consumption
40 mAMAX (230 Vac)
Memory
permanent for configuration and user settings (last data operating memory)
Linear resolution
200 - 100 - 50 - 20 - 10 - 5 - 2 - 1 - 0.5 μm
0.01 - 0.005 - 0.002 - 0.001 - 0.0005 - 0.0002 - 0.0001 - 0.00005 - 0.00002 inch
Angular resolution
1 - 0.5 - 0.2 - 0.1 - 0.05 - 0.02 - 0.01 - 0.005 - 0.002 - 0.001 °
Operating temperature
0 °C ÷ 50 °C
Storage temperature
-20 °C ÷ 70 °C
Weight
450 g
Options
UR2
-S
SSI
/
80 mAMAX (110 Vac)
/
350 mAMAX (24 Vac)
RELAY OUTPUTS
SERIAL OUTPUT RS-232
ABSOLUTE (SSI) ENCODER INPUT
ABSOLUTE (SSI) ENCODER PARAMETERS
Clock frequency
125 / 250 / 500 kHz
Number of position bits
8-32 bit
Output code
Binary, Gray
Optional bits
Parity bit, Error bit
Pag. 1/2
GIVI MISURE S.R.L. A SOCIO UNICO
C.F. e Iscrizione al Reg. Imprese di Monza e Brianza n° 04355540156 - Cap. Soc. € 51.480,00 I.V.