Model 2600 pages
800-257-3872
159 Swanson Rd., Boxborough, MA 01719/Telephone: 978-263-1400/Fax: 978-264-0292
Multi-SenseTM Series - Model 260
Very Low Differential Multi-Confi gurable
Pressure Transducer
Unidirectional Ranges: 0.1 - 10 in. W.C. to .25 - 2.5 kPa FS
Bidirectional Ranges: ±0.1 - 10 in. W.C. to ±.25 - 2.5 kPa FS
Air or Non-Conducting Gas
Visit Setra Online:
http://www.setra.com
ments. The units are temperature compsensated
to within ±0.03%FS/oF (0.054%FS/oC) for
zero and span.
The Model 260 utilizes an all stainless steel
micro-tig welded sensor. The tensioned
stainless steel diaphragm and insulated stainless
steel electrode, positioned close to the
diaphragm, form a variable capacitor. Positive
pressure moves the diaphragm toward the
electrode, increasing the capacitance. A decrease
in pressure moves the diaphragm away
from the electrode, decreasing the capacitance.
The change in capacitance is detected
and converted to a linear DC electrical signal
by Setra’s custom ASIC technology.
Target Users
œ Service/Retrofi t Friendly
œ Small Users - Inventory &
Installation Savings
œ Sub-Contractors - Quick
Installation
œ Flexible for Building
Specifi cation Changes
œ Service Technicians-
Quick and Accurate
Reconfi gurations
Features
¡ Optional 4 Digit LCD
¡ Field Selectable Multi-
Range
¡ Field Selectable Multi-
Output
¡ Simple 5-Step Setup
¡ Field Accessible Push
Button Zero and Span
¡ Hinged Cover
¡ External Mounting Tabs
¡ Unregulated AC/DC
Operation
¡ Microprocessor Based
Electronics - Guarantees
Range to Range Performance
¡ NIST Traceable
¡ Fire Retardant Case
(UL 94 V-0 Approved)
¡ Meets CE Conformance
Standards
¡ Fully RoHS Compliant
Setra Systems 260 pressure transducers
sense differential or gauge (static)
pres sure and convert this pressure
difference to a proportional electrical output
for either fi eld selectable unidirectional
or bidirectional pressure ranges. The 260
Series is offered with fi eld selectable high level
analog outputs of 0 to 5, and 0 to 10 VDC, or
4 to 20 mA.
Used in Building Energy Management
Systems, these transducers are capable of
measuring pressures and flows with the
performance necessary for proper building
pressurization and air fl ow control.
The 260 Series transducers can be confi gured
for air pressure ranges as low as 0.1 in. W.C.
full scale, with pascal ranges as low as 25 Pa
full scale. Static standard accuracy is ±1.0% full
scale in normal ambient temperature environ-
Model Unidirectional Bidirectional
MS1 0.1, 0.25, 0.5, 1.0 in. WC FS ±0.1, 0.25, 0.5, 1.0 in. WC FS
MS2 1.0, 2.5, 5.0, 10 in. WC FS ±1.0, 2.5, 5.0, 10 in. WC FS
MS3 25, 50, 100, 250 Pa FS ±25, 50, 100, 250 Pa FS
MS4 .25, .50, 1.00, 2.5 kPa FS ±.25, .50, 1.00, 2.5 kPa FS
Ranges
Uni d irectional Optional Static Probe Designed
with a Gasket to Seal Against the
Duct.
U.S. Patent nos. 4093915; 4358814; 4434203; 6019002; 6014800.
Other Patents Pending.