Heavy Duty Industrial Temperature Sensor (HDF)0 pages
Data Sheet No 048
PRODUCT DESCRIPTION
Heavy Duty
Industrial Temperature Sensor
Heavy Duty
Industrial
Temperature
Sensor
with solid drilled flanged thermowell
Many areas of process plant demand temperature sensors with a
rugged construction to meet both the demands of the process and
the installation environment. A thermowell machined from solid bar
stock offers a higher integrity for those more demanding process parameters and a flanged process connection enables it’s use in higher
process pressures. The choice of connection head type and extension also allows a specification to be drawn up that will satisfy most
requirements.
S P E C I F I C A T I O N
MECHANICAL
Thermowell
Materials :
304, 316 or 310 stainless steel, Hastelloy C, Monel,
Nickel 200, Titanium.
Process connection : minimum flange size ½” ANSI 150 RF, but BS, metric and flanges to JIS standards are also available.
Lagging extension :
½” NB pipe plain extension or ½” NB nipple/union/
nipple in carbon steel, galvanised or 316 stainless
steel.
Connection head :
in die-cast aluminium with screw cap, retention
chain and M20 cable entry or ½” NPT conduit connection. Environmental rating to IP67.
ELECTRICAL
Spring loaded insert
Sheath :
321, 316L or 310 stainless steel, 6mm OD (length to
suit thermowell) and fitted with a spring loaded ceramic terminal block.
Resistance Thermometer
Detector :
single or duplex PT100 with 3 wire connection ,
Class ‘B’ or ‘A’ tolerance and to BS EN 60751:1996.
Product code :
HDF
Operating range :
Thermocouple
Element :
Operating range :
-50 to +380°C (-58 to+716°F)
single, duplex or triplex elements, types ‘T’ (Cu/
Con), ‘E’ (NiCr/Con), ‘J’ (Fe/Con) ‘K’ (NiCr/NiAl) or
‘N’ (Nicrosil/Nisil) to BS EN 60584-1:1996.
-50 to +850°C (-58 to+1562°F), depending on
thermocouple type.
A temperature transmitter with a 4 to 20mA output can be supplied in place
of the connection block for both hazardous and non-hazardous duties. Other
dimensions and tolerances outside the above specifications may also be
available on application.
©Thermal Detection 2007
Thermal Detection Limited
Unit 6, Orde Wingate Way
Primrose Hill Industrial Estate
Stockton-on-Tees England TS19 0GA
Tel
Fax
Email
Website
+44 (0) 1642 602878
+44 (0) 1642 618307
tdl@thermal-detection.com