AC Current Sensor & Controls ECS Series0 pages
نسخه متنی
"
"
Over/Under Current Sensing ECS Series Current Sensor | ||||||||||||||||||||||||||||||||||||||||||||||||
Description The ECS Series of Single Phase AC Current Sensors is a universal, overcurrent or undercurrent sensing control. Its built-in toroidal sensor eliminates the inconvenience of installing a stand-alone current transformer. Includes onboard adjustments for current sensing mode, trip point, and trip delay. Detects over or under current events like locked rotor, loss of load, an open heater or lamp load, or proves an operation is taking place or has ended. | ||||||||||||||||||||||||||||||||||||||||||||||||
Operation Input voltage must be supplied at all times for proper operation. When a fault is sensed throughout the trip delay, the output relay is energized. When the current returns to the normal run condition, the output and the delay are reset. If a fault is sensed and then corrected before the trip delay is completed, the relay will not energize and the trip delay is reset to zero. Adjustment Select the desired function, over or under current sensing. Set the trip point and trip delay to approximate settings. Apply power to the ECS and the monitored load. Turn adjustment and watch the LED. LED will light; turn slightly in opposite direction until LED is off. Adjustment can be done while connected to the control circuitry if the trip delay is set at maximum. Connection | Function | |||||||||||||||||||||||||||||||||||||||||||||||
Overcurrent | ||||||||||||||||||||||||||||||||||||||||||||||||
TP | ||||||||||||||||||||||||||||||||||||||||||||||||
■ Toroidal Through Hole Wiring ■ 0.5...50 A Trip Point ■ Adjustable or Factory Fixed Trip Delays ■ 10 A SPDT Isolated Output Contacts ■ 5% Trip Point Hysteresis (Dead Band) Approvals: | ||||||||||||||||||||||||||||||||||||||||||||||||
C-A-»__I-1_ | ||||||||||||||||||||||||||||||||||||||||||||||||
OC NO NC | ||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||
Je NO NC | ||||||||||||||||||||||||||||||||||||||||||||||||
TP = Trip Point R = Reset OC = Monitored Current NO = Normally Open Contact NC = Normally Closed Contact A = Sensing Delay On Start Up TD = Trip Delay | ||||||||||||||||||||||||||||||||||||||||||||||||
Relay contacts are isolated. Dashed lines are internal connections. V = Voltage I> = Overcurrent I< = Undercurrent W = Insulated Wire Carrying Monitored Current | ||||||||||||||||||||||||||||||||||||||||||||||||
Jering Table | ||||||||||||||||||||||||||||||||||||||||||||||||
Accessories | ||||||||||||||||||||||||||||||||||||||||||||||||
Series —ECS -(selectable over or under current sensing) ECSH -(overcurrent sensing) —ECSL - (undercurrent sensing) | nput 1 - 12 V DC -2 - 24 V AC -3 - 24 V DC -4 - 120 V AC -6 - 230 V AC | Trip Point Fixed - Specify 2 ... 50 A in 1 A increments Adjustable Ranges -0 - 0.5 ... 5 A - 2 ... 20 A - 5 ... 50 A | Trip Delay | Sensing Delay on Start up -Blank - 0 s | ||||||||||||||||||||||||||||||||||||||||||||
Female quick connect P/Ns: P1015-13(AWG 10/12) P1015-64 (AWG 14/16) P1015-14(AWG 18/22) | ||||||||||||||||||||||||||||||||||||||||||||||||
-F | Factory Fixed: Specify .08 ... 50 s | |||||||||||||||||||||||||||||||||||||||||||||||
1 s 2 s 3 s 4 s 5 s 6 s | ||||||||||||||||||||||||||||||||||||||||||||||||
Adjustable Ranges -A - 0.150 ... 7 s - 0.5 ... 50 s | ||||||||||||||||||||||||||||||||||||||||||||||||
g | ||||||||||||||||||||||||||||||||||||||||||||||||
3 Z | ||||||||||||||||||||||||||||||||||||||||||||||||
See accessory pages for specifications. | ||||||||||||||||||||||||||||||||||||||||||||||||
Example P/N: ECS4 | Fixed - ECSH610AD | |||||||||||||||||||||||||||||||||||||||||||||||
8.4 | Low Voltage Products & Systems | |||||||||||||||||||||||||||||||||||||||||||||||
1TRC001009C0201 | ||||||||||||||||||||||||||||||||||||||||||||||||
ABB Inc. • Sales Information 1-888-385-1221 • Technical Assistance 1-800-377-SSAC (7722) • www.ssac.com |