Digital Program Controller DP1000G0 pages
DP1000G
GRAPHIC PROGRAM CONTROLLER
DP1000G series is a graphic program
controller employed high visibility 5.6 TFT
color LCD display. Maximum 200 types of
program pattern (Maximum 4000 steps) are
stored and performance pattern is selectable.
Control cycle of 0.1 sec, 5 digits display, high
speed and high accuracy of 0.1% indicating
accuracy are realized.
FEATURES
Employing clear 5.6 TFT color LCD display
Graphic screen of pattern progress status, display of PV
value/SV value/pattern/step/time and various monitor functions such as program progress enlarged display, enlarged data display and bargraph display are prepared.
Easy program pattern settings on graphic screen
Maximum 200 patterns/Maximum 4000 steps settings, pattern repeat, linking between patterns and endless program setting are available.
Parameter settings per step
Each parameter setting such as SV/PV start, guarantee
soak and time signal is available per step.
High performance and universal input
Input selection from each range of thermocouple, DC voltage/current and resistance thermometer are available
and unit has performance of 5 digit display, accuracy rating of 0.1% and sampling period of 0.1sec.
Storing settings in CF card
Setting management is easy as all settings including setting program pattern and each parameter are stored in CF
card and readout from it.
PC software allows you to edit program pattern and parameter.
Various control application functions
Heating/cooling output is applicable as control output has
ON-OFF pulse type, current output type, SSR drive pulse
type and voltage output type.
Abundant external input/output
Unit with external input 16 points and external output 28
points enables function assignment. Synchronized operation with peripherals are easy. Serial communications interface and transmission signal output are also prepared.
MODELS
D P1 0
G
Control mode (output No.1)
1 : ON-OFF pulse PID
2 : ON-OFF servo PID (standard load spec)
3 : Current output PID (general type 4 to 20mA DC)
5 : SSR drive pulse PID
6 : Voltage output PID (general type 0 to 10V DC)
8 : ON-OFF servo PID (minimal load spec)
A : Current output PID (high accuracy type 4 to 20mA DC)
B : Current output PID (high accuracy type 1 to 5mA DC)
C: Voltage output PID (high accuracy type 0 to 10V DC)
Control mode (output No.2)
0 : None
1 : ON-OFF pulse PID*1 OP
3 : Current output PID (general type 4 to 20mA DC) *1 OP
5 : SSR drive pulse PID*1 OP
6 : Voltage output PID (general type 0 to 10V DC)*1 OP
A : Current output PID (high accuracy type 4 to 20mA DC)*1 OP
B : Current output PID (high accuracy type 1 to 5mA DC)*1 OP
C: Voltage output PID (high accuracy type 0 to 10V DC)*1 OP
Communications interface
0 : None
R: RS232C (COM1)OP
S : RS485 (COM1)OP
A : RS422A (COM1)OP
B : RS232C (COM1) + RS232C (COM2)OP
C: RS485 (COM1) + RS232C (COM2)OP
D: RS422A (COM1) + RS232C (COM2)OP
E : RS232C (COM1) + RS485 (COM2)OP
F : RS485 (COM1) + RS485 (COM2)OP
G: RS422A (COM1) + RS485 (COM2)OP
Transmission signal output 1
0 : None
1 : 4 to 20mAOP
2 : 0 to 1VOP
3 : 0 to 10VOP
4 : 1 to 5VOP
Transmission signal output 2
0 : None*
1 : 4 to 20mAOP
2 : 0 to 1VOP
3 : 0 to 10VOP
(Adding only transmission signal output 2 is not available)
Case color
G: Gray
B : Black
External input/ output signal
0 : NoneOP
1 : Digital input/ output (non voltage contact input)
2 : Digital input/ output (External power supply spec for only input)OP
Transmitter power supply
0 : None
1 : Transmitter power supplyOP
Interchangeable with DP series
DP series are easily replaced with DP1000G which inherited characteristics of DP series such as function, operability and terminal arrangement/configuration.
*1
*2
Selectable when control mode (output1) is 1,3,5,6,A,B,C.
COM1 is exclusive use for rear port,
COM2 is rear port and front port switchable.
OP Option
PSE-362
"