Strip Chart Recorder EL3000 pen0 pages
EL3000 SERIES
100mm CHART ANALOG RECORDER (PEN WRITING TYPE)
EL 3000 series are analog recorders sized 144 x
144mm with 100mm width chart which have 3 types
of 1-pen, 2-pen and 3-pen.
The unit starts recording as soon as the power
supply and input are connected and it is also easy
to operate.
Scale plate, input range and function of the
recorder can be selected for various purpose and
applications as many kinds of options are prepared.
FEATURES
Universal power supply
Universal power supply with voltage range of 100 to
240V AC is applied. (50/60Hz switchable)
Linear temperature scale
Temperature scale of thermocouple and resistance
thermometer input is a linear scale that is excellent in
reading indication value.
Standard 6 chart speeds
6 chart speeds (5,10,20,40,80,160mm/h) are
switchable as standard. 5 chart speed and hour/minute
change are prepared as option.
Unit structure and light-weight
Light-weight (50% of the previous unit weight) was
realized by easy maintenance unit structure.
Alarm setting (individual input alarm) as standard
Higher and lower limit alarm can be programmed for
each channel. Alarm value is easy to be programmed
by pointer location. You can check the alarm by front
LED lighting. Alarm output is prepared as option.
MODELS
1-pen type
2-pen type, 3-pen type
EL3P1 -
EL3
Input signals
5 : Thermocouple/DC voltage
7 : Resistance thermometer
Thermocouple with burnout/DC voltage
Built-in voltage divider input (option)*1
Input and scale plate (option)
0 : Standard input + standard scale plate
1 : Non-standard input
(Including current input, and built-in
voltage divider) + standard scale plate
2 : Standard input + non-standard scale plate
3 : Non-standard input
(Including current input, and built-in
voltage divider) + Non-standard scale plate
Alarm output (option)
0 : None
1 : 2 alarm outputs
Chart speed and burnout (option)
0 : 6-speed+ burnout disabled
1 : 6-speed + up-scale burnout
2 : 6-speed + down-scale burnout
A : 5-speed hour/minute change + burnout disabled
B : 5-speed hour/minute change + up-scale burnout
C : 5-speed hour/minute change+ down-scale burnout)
*1: Optional built-in voltage divider and thermocouple/resistance thermometer burnout input is only type "7".
*2: Input and scale selection are needed for non-standard input and non-standard scale plate. 1st pen must be
selected as thermocouple input.
*3 Burnout are programmed together for all channels for thermocouple/ resistance thermometer input.
1
Input points
F : 2 pen
G : 3 pen
1st pen input and scale plate*2
0 : Standard input + standard scale plate
1 : Non-standard input (Including current input
and built-in voltage divider) +standard scale plate
2 : Standard input + non-standard scale plate
3 : Non-standard input (Including current input
and built-in voltage divider) +non-standard scale plate
2nd pen input and scale plate*2
0 : Standard input + standard scale plate
1 : Non-standard input (Including current input
and built-in voltage divider) +standard scale plate
2 : Standard input + non-standard scale plate
3 : Non-standard input (Including current input
and built-in voltage divider) +non-standard scale plate
3rd pen input and scale plate*2
N : None (for 2 pen)
0 : Standard input + standard scale plate
1 : Non-standard input (Including current input
and built-in voltage divider)+ standard scale plate
2 : Standard input + non-standard scale plate
3 : Non-standard input (Including current input
and built-in voltage divider) +non-standard scale plate
Alarm output (option)
0 : None
2 : Alarm output 4points/6points
(2-pen type : 4 points, 3-pen type : 6 points)
Chart speed and burnout (option)*3
0 : 6-speed + burnout disabled
1 : 6-speed + up-scale burnout
2 : 6-speed + down-scale burnout
A : 5-speed hour/minute change + burnout disabled
B : 5-speed hour/minute change + up-scale burnout
C : 5-speed hour/minute change + down-scale burnout
PSE-361
"