Strip Chart Recorder EL3000 dotting0 pages
EL3000 SERIES
100mm CHART
ANALOG RECORDER (DOT PRINTING TYPE)
EL3000 series is a dot printing type analog recorder
sized 144x144mm with 100mm width chart.
The unit starts recording as soon as the power
supply and input are connected and it is also easy
to operate.
Scale plate, input range and function of the
recorder can be selected for various purpose and
applications as many kinds of options are prepared.
FEATURES
Universal power supply
Universal power supply with voltage range of 100 to
240V AC (50/60Hz) is applied.
Linear temperature scale
Temperature scale of thermocouple and resistance
thermometer input is a linear scale that is excellent in
reading indication value.
Standard 6 chart speeds
6 chart speeds (5,10,20,40,80,160mm/h) are
switchable as standard.
5 chart speed and hour/minute change are prepared as
option.
Alarm setting (common alarm) as standard
Higher and lower limit alarm can be programmed for
every point. Alarm value is easy to be programmed by
pointer location.
You can check the alarm by front LED lighting.
Alarm output is prepared as option.
CE marking
The EL recorder is conformed to the rules of safety
standards of CE. (Conformity pending)
Unit structure and light-weight
Light-weight (50% of the previous unit weight) was
realized by easy maintenance unit structure.
Employing removable type terminal board
Employing easy connecting removable type terminal
board.
MODELS
EL3D
Input point
1 : 1point
2 : 2points
3 : 3points
6 : 6points
Input signals
5 : Thermocouple/DC voltage
7 : Resistance thermometer
Thermocouple with burnout/DC voltage
Built-in voltage divider input (option)*1
Input and scale plate (option)*2
0 : Standard input + standard scale plate
1 : Non-standard input
(Including current input, and built-in
voltage divider) + standard scale plate
2 : Standard input + non-standard scale plate
3 : Non-standard input
(Including current input, and built-in
voltage divider) + Non-standard scale plate
Alarm output (option)
0 : None
1 : 2 alarm outputs
Chart speed and burnout (option) *3
0 : Standard 6-speed+ burnout disabled
1 : Standard 6-speed + up-scale burnout
2 : Standard 6-speed + down-scale burnout
A : Standard 5-speed hour/minute change
+ burnout disabled
B : Standard 5-speed hour/minute change
+ up-scale burnout
C : Standard 5-speed hour/minute change
+ down-scale burnout)
*1: Optional built-in voltage divider and thermocouple/residence thermometer burnout input is only type "7".
*2: Double scale is available.
Input and scale selection are needed for non-standard input and non-standard scale plate.
*3: Burnout on all channels is programmed together for thermocouple/residence thermometer input.
1