Digital Program Setter0 pages
KP3000 SERIES
DIGITAL PROGRAM SETTER
The KP3000 series is a 96x96mm digital program
setter with the analog output accuracy of ±0.1% and
maximum 30 program patterns (maximum 19 steps/
pattern).
Output signal can be specified from analog output type
and digital output type. By combination with a digital
indication controller with digital input, the configuration
of low cost program control system is enabled.
ipnnn
I FEATURES
► Program pattern
Settings of maximum 19 steps per pattern and maximum
30 sets of patterns are enabled. Repeating of a whole pro-
gram pattern, linking of program patterns and repeating of
a specific step in a program pattern are enabled, too.
►Analog output type and digital output type
Output of setting unit is selected from high accuracy
(0.1 %FS) analog output type and digital output type which
has no setting error by using communications function.
►Communications 2-port type provided
Models with 2 communications ports are available. In addi-
tion, speeding up and highly-functionalization of communi-
cations have been realized. For example, you can use 1
port for high order communications with a personal comput-
er and another port for the communications remote (digital
remote) function. The communications protocol can be arbi-
trarily selected from [MODBUS] and [PRIVATE].
In the digital output type, however, 1-port type of communi-
cations is only available.
► DI/DO arbitrarily-allocation
When the digital input (Dl) or the digital output (DO) is ad-
ded, arbitrarily-allocation for assigning functions to those
DI/DO's is enabled. It is the function enabling allocations
such as [External drive input] to DM to DI3 and [Pattern se-
lecting input] to DI4 to DI6.
►Conforming to international safety standards and Euro-
pean directives (CE)
The controller is conformity with European directives (CE),
and is UL and c-UL approved.
►Conforming to RoHS
The controller is an environmental consideration product
which does not contain directed hazardous substances
such as lead, etc.
■ MODELS
KP3-nocnnn-nnn
Output signal
Digital output (RS422A)
Analog output (4 to 20mA)
Analog output (0 to 10V)
Analog output (0 to 1V)
Analog output (Others)
Digital output (RS485)
B:
D:
1
2
4
5
6
7
-1st zone*
0: None
P: 6 Digital inputs
T: 6 Digital outputs
-2nd zone*
0: None
P: 6 Digital inputs*1
T: 6 Digital outputs*1
-3rd zone*
0: None
R: Communications 1 port (RS232C)
+ 3 Digital inputs*2
A: Communications 1 port (RS422A)
+ 1 Digital input*3
S: Communications 1 port (RS485)
+ 3 Digital input*2
Communications 2 ports (RS232C + RS232C)
+ 1 Digital input*4
Communications 2 ports (RS232C + RS422A)
+ 1 Digital input*4
Communications 2 ports (RS232C + RS485)
+ 1 Digital input*4
E: Communications 2 ports (RS485 + RS232C)
+ 1 Digital input*4
F: Communications 2 ports (RS485 + RS422A)
+ 1 Digital input*4
G: Communications 2 ports (RS485 + RS485)
+ 1 Digital input*4
P: 6 Digital inputs*4
T: 6 Digital outputs*4
U: 8 Digital inputs*4
W: 8 Digital outputs*4
Y: 3 Digital inputs
+ 5 Digital outputs*4
Z: 4 Digital inputs
+ 4 Digital outputs*4
-Case color
G: Gray
B: Black
Panel sealing and terminal cover*
0: None
1: Terminal cover
2: IP54 panel sealing
3: IP54 panel sealing + Terminal cover
Power supply voltage
A: 100 to 240V (AC)
D: 24VAC/24VDC
* Option
*1 It can be selected when the control signal is 1 or 7 only.
*2 The digital input is 1 point for the control signal of 1 or 7.
*3 It can be selected when the control signal is 2, 4, 5, 6 or 7 only.
*4 It can be selected when the control signal is 2, 4, 5 or 6 only.
Note: For options common to 1st zone, 2nd zone and 3rd zone, assign them in
order of [P] and [T] from 3rd zone first
PSE-360A
"