HAUG lonization -for the limination of electrostatic charges
Statik-Air 08 - System Dr. Escherich
Statik-Air 08 is used for contact-free cleaning with simultaneous extraction of visible dust and smaller particles.
Function
Cleaning and elimination of electrostatic charges from material webs in the same process by using ionized compressed air (ill.2). The integrated extractor ensures an optimum and residue-free degree of surface cleaning.
The following ionizing bars can be combined with the Statik-Air 08 housing:
Ionizing bar El RN
镕 Ionizing bar El RD
Ionizing bar El VS
Օ Ionizing bar El Ex T
Pulsed operation
The application of Statik-Air systems in pulsed operation can be recommended for media transported with intermediate distances/gaps.
Advantage: reduced costs (e.g. for compressed air). Pulsed operation can be controlled by external input to the switchgear, e.g. using photoelectric sensors, proximity switches or other potential-free contacts.
ill.2
Continuous operation
The application of Statik-Air systems in continuous operation can be recommended if the medium to be cleaned passes through continously.
Switchgear
The switchgear is equipped with 3 functional modules:
Power supply with power circuit breaker, motor circuit breaker for extractor fan, ON/OFF switch and control lamps. Should it be necessary to connect two extractor fans to one switchgear, the relevant versions can also be supplied.
Օ Solenoid valve for compressed air control with time-delay switch for pulsed operation.
High-voltage power pack with 4 high-voltage terminals. The watchdog integrated in the secondary area signals a drop below the corona inception voltage.
ill.4
Compressed air
Compressed air of a quality suitable for spraying applications must be available, i.e. it must be free of oil and water. The upstream installation of a service unit with integrated oil and water separator is recommended.
Web speeds
The maximum web speed of the standard version is approx. 80 m/min. Higher speeds are available on request.
Air consumption diagram
Air consumption in N m3/h as a function of extraction width and operating pressure (ill.3)
Typical applications
Plastics, furniture, paper, print, film, foil, automotive, electrical and other industries.
ill.3
HAUG GmbH & Co. KG
Germany
200
Tol. ±15%
3 bar...-"-'^
- «■......
1 barח-**~~~~~~
Friedrich-List-Str. 18 D-70771 Leinf.-Echterdingen Phone: +49 711 / 94 98-0 Telefax: +49 711 /94 98-298
HAUG Biel AG
www.haug.de E-mail: info@haug.de
Switzerland
150
c o
H. 100
50
0
Johann-Renfer-Str. 60 CH-2500 Biel-Bienne 6 Phone: +41 32 / 344 96 96 Telefax: +41 32 / 344 96 97
50
100 150 170
Extraction width in cm
www.haug-ionisation.com E-mail: info@haug-biel.ch