OA-TO Turbine Oil Analysis0 pages
HY-PRO FILTRATION
OA-PATLKF (replaces OA1)
Oil Analysis Kits
Bottle Sample Oil Analysis
ISO4406:1999 particle count (4/6/14)
Spectroscopy, FTIR, Wear Metals
AN (acid number) mg KOH/g
Water Content by KF (ppm)
Hy-Pro qualified objective lab results
Prepaid tests in 10 pack cartons
Benefits of Fluid Monitoring
Fluid conditioning monitoring is critical for making
proper condition based contamination solution
recommendations. With a complete snapshot of
the fluid condition from oil analysis Hy-Pro can help
diagnose any problems caused by contamination or
fluid degradation and craft a solution to yield optimum
system reliability and yield maximum useful fluid life.
When used in a routine sampling program the OA1 oil
analysis kit results provide all the information needed
to trend changes in fluid condition and identify types of
contamination to catch component or fluid problems
before they result in unplanned downtime or premature
fluid replacement.
Sampling Procedure Requirements
Obtaining Representative Sample
•t
For oil analysis data to be most effective the sample
must be acquired properly so that it is representative
of the fluid that is going to sensitive bearings hydraulic
components. Select a position of maximum turbulence
and constant flow.
•t
If general system cleanliness is required, sample from
a main flow line upstream of a filter or from an active
reservoir
•t
If the cleanliness of the fluid entering a sensitive
component is required, sample in a main flow line
upstream of the component
•t
Identify best sample port location and type
•t
Sample must be representative of the system
•t
Completely purge sample port
•t
Sample should be taken during system
operation
•t
Rinse sample bottle 3 times with oil from sample port oil
before collecting the sample
•t
Fluid should be at operating temperature
•t
Develop a procedure to ensure consistency
•t
Sampling method must not introduce
contamination
•t
Sample port must be properly flushed to prevent
introduction of background contamination
•t
Only use sampling bottles pre-cleaned per
ISO3722