Front-End Module Datasheets - EMI filter up to 300 W0 pages
MIL-STD-461 EMI INPUT FILTERFGDS-20A-50V : up to 20A CURRENT
nnHi-RelGrade Hi-Rel
Grade
nn20A EMI Filter Module9 to 50 VDC Input RangeMIL-STD-461D/E Compliant
? DO-160-C/D/E/F requirements : ? Conducted Emission (CE) ? ? Conducted Susceptibility (CS) Section 21 power lines, emission over 15KHz to 30MHz, category B, AZ & LMH ? ? Section 22 : lightning induced transient susceptibilityIn addition, this filter withstands in a transpa-rent state without dammage the transient and
spike requirements of : Section 20 power lines, frequency 10KHz to 400MHz To comply with MIL-STD-461D/E/F power leads :Օ CE 102 : Emission requirement over 10 KHz to 10MHz CS 101 : Susceptibility requirement over 30Hz to 150KHz
Օ CS 114 : Susceptibility requirement over 10KHz to 400MHz CS 115 : Susceptibility requirement for spikesՕ To comply with DO-160C/D/E/F power lines : Conducted emission requirement over 15 KHz to 30MHzՕ Conducted susceptibility requirement over 10Hz to 400MHz Susceptibility requirement for induced transientsՕ Temperature range : operating temperature : -40հC/+105C case
Е storage temperature : -55C/+125аC ? MIL-STD-704A with 80V/100ms & 600V/10s ? MIL-STD-1275B with 100V/50ms & 250V/70յsThe FGDS-20A-50V is suitable for all GAIA ConverterDC/DC converters and DC architecture ? from 50W up to 300W power ? up to 20A input current ? up to 50V permanent input voltage. >
1-General
the US MIL-STD-461 rev D, E and rev F The GAIA Converter filter module FGDS-20A-50V
provides a state-of-the-art product to fulfillElectromagnetic Interferences (EMI) requirements forAerospace and Defence applications.
The FGDS-20A-50V is a very compact and low loss
solution for applications requiring up to 20A input
current.The FGDS-20A-50V complies with major standardsincluding : ? the international DO-160 rev C, D, E and rev FIn particular, the filter module is compliant withthe following requirements of MIL-STD-461D/E
standards : ? MIL-STD-461D/E/F Part 2. & 3. requirements : Օ Conducted Emission (CE) ? ? Conducted Susceptibility (CS) CE102, power leads, emission over 10KHz to 10MHz, basic curve ? ? ? CS115, spikes, bulk cable injection, calibrated spike CS114, bulk cable injection, frequency 10KHz to 400MHz, CS101, power leads, frequency 30Hz to 150KHz, curve #1 >
2-Product Selection
nnFGDS-20A-50V (/T) and/or (/S) nn(/T) : option for -55C start up operating temperature.(/S) : option for screening and serialization REDEFINING THE SOURCE OF POWER
nnЩ
nnGaia Converter FC05-050.10/05 Revision A For locations, phone, fax, E-Mail see back cover size="-1">
"