Front-End Module Datasheets - EMI filter up to 50 W0 pages
MIL-STD-461 EMI INPUT FILTERFGDS-2A-50V up to 2A CURRENT
nnHi-RelGrade Hi-RelGrade
? MIL-STD-461D/E/F Part 2. & 3. requirements : ? Conducted Emission (CE) ? ? Conducted Susceptibility (CS) CE102, power leads, emission over 10KHz to 10MHz, basic curve ? ? ? CS114, bulk cable injection, frequency 10KHz to 400MHz, CS115, spikes, bulk cable injection, calibrated spike CS101, power leads, frequency 30Hz to 150KHz, curve #1 >
nn2A EMI Filter Module9 to 50 VDC Input RangeMIL-STD-461C/D/E/F Compliant
? DO-160-C/D/E/F requirements : ? Conducted Emission (CE) ? ? Conducted Susceptibility (CS) Section 21 power lines, emission over 15KHz to 30MHz, category B, AZ & LMH ? Section 20 power lines, frequency 10KHz to 400MHzIn addition, this filter withstands in a transparentstate without dammage the transient and spike
requirements of : To comply with MIL-STD-461D/E/F power leads :Օ CE 102 : Emission requirement over 10KHz to 10MHz CS 101 : Susceptibility requirement over 30Hz to 150KHz
Օ CS 114 : Susceptibility requirement over 10KHz to 400MHz CS 115 : Susceptibility requirement for spikesՕ To comply with MIL-STD-461C power leads : CE 03 : Emission requirement over 15KHz to 50MHzՕ CS 01 : Susceptibility requirement over 30Hz to 50KHz CS 02 : Susceptibility requirement over 15KHz to 400MHz
Օ CS 06 : Susceptibility requirement for spikes To comply with DO-160C/D/E/F power lines :Օ Conducted emission requirement over 15KHz to 30MHz Conducted susceptibility requirement over 10KHz to 400MHzՕ Susceptibility requirement for induced transients Temperature range : Օ operating temperature : -40C/+105аC case storage temperature : -55հC/+125C ? from 4W up to 50W power ? MIL-STD-704A with 80V/100ms & 600V/10еs ? up to 2A input current ? MIL-STD-1275B with 100V/50ms & 250V/70sThe FGDS-2A-50V is suitable for all GAIA
Converter DC/DC converters and architecture ? up to 50V permanent input voltage. Օ the US MIL-STD-461 rev C, D, E and rev F ? the international DO-160 rev C, D, E and rev FIn particular, the filter module is compliant withthe following requirements of MIL-STD-461
standards : >
1-General
The GAIA Converter filter module FGDS-2A-50V
provides a state-of-the-art product to fulfill
Electromagnetic Interferences (EMI) requirements
for Aerospace/Defence applications.
The FGDS-2A-50V complies with major standards
including : ? MIL-STD-461C Part 2. & 3. requirements : Conducted Emission (CE) ? ? CE03, power leads, emission over 15KHz to 50MHz, narrowband, Class A1 CE03, power leads, emission over 15KHz, broadband, Class A1 curve# 1 & 2 ? ? Conducted Susceptibility (CS) ? CS06, power leads, spike #1 CS02, power leads, frequency 15KHz to 400MHz, class A1 ? CS01, power leads, frequency over 30Hz to 50KHz, class A1, consult factory
for criteria >
2-Product Selection
nnFGDS-2A-50V (/T) and/or (/S) nn(/T) : option for -55հC start up operating temperature.(/S) : option for screening and serialization REDEFINING THE SOURCE OF POWER
nnGaia Converter FC05-050.10/08 Revision C For locations, phone, fax, E-Mail see back cover size="-1">
"