Socan - AC Current Sensor SCK1TB0 pages
SCK1T‐0‐20mA Current Transducer technical parameters
Dimensionin mm. 1mm=0.0394 inch):
SCK1T-0-20mA
Model
Parameters(25°C)
50A
100A
200A
300A
Nominal Rms Current (Ipn)
±50AT
±100AT
±200AT
±300AT
Measuring Range (Ip)
150AT
300AT
600AT
750AT
Load resistance Rmax
10-200Ω
Output current
±0-20mA
DC
Working voltage
±12V
Accuracy @ Ta=25°C
±1% FS
Linearity @ Ta=25°C
±1% FS
Withstand voltage
2.5kVrms/50Hz/min
Offset Current
0.1mA < ±1%
Offset temperature characteristics
< ±0.08%/°C
< ±0.05%/°C
Thermal drift of Vo
< ±0.2% /°C
< ±0.1 /°C
< ±0.1mA
Hysteresis offset
Response time
< 30mS
Current consumption
<±25mA + output current
Operating temperature
-40~+80 °C
Storage temperature
-40~+85 °C
Instructions:
1. SCK1TB Model is current ±0‐20mA output.
2. This model also have voltage output for your choice.
3...Advantages: Excellent accuracy, low power consumption, high liability and good current overload capability.
Caution: Incorrect wiring may damage the sensor
Shenzhen SoCan Technologies Co.,Ltd
East Floor 3, No.2 Building, Shunheda Factory Liuxiandong Industrial Park,
Xili Town,Nanshan Dist 518052, Shenzhen, China
T: 86‐0755‐86242301 F: 86‐0755‐86242302 @: info@szsocan.com
Website: szsocan.com