Topcable_eng_32_topsolar_ZZ-F0 pages
Based on:
TÜV 2Pfg 1169-08 / UTE C 32-502
LOW VOLTAGE CA: 0,6/1kV · CC: 1,8 kV
TOPSOLAR PV
TOPSOLAR PV ZZ-F
ZZ-F
DIMENSIONS
Sección
(mm2)
Cables for photovoltaic solar installations
1 x 1,5
1 x 2,5
1x4
1x6
1 x 10
1 x 16
1 x 25
1 x 35
DESIGN
Conductor
Class 5 tinned copper, based on EN 60228
Insulation
LSZH thermosetting Rubber (EI6 type)
Diámetro
(mm)
4,9
5,0
5,6
6,2
7,2
8,2
10,8
11,9
Weight
(Kg/km)
40
45
61
80
125
180
294
390
Open Air
(A)
30
41
55
70
98
132
176
218
inst. on
surface
(A)
29
39
52
67
93
125
167
207
inst. adjadjoining
to surface
(A)
24
33
44
57
79
107
142
176
Voltage drop
(V/A · km)
38,0
23,0
14,3
9,49
5,46
3,47
2,23
1,58
Outer sheath
LSZH thermosetting rubber (type EM8). Red or black colour.
APPLICATIONS
Flexible cables for mobile service and for fixed installations. Specially designed for
interconnection of photovoltaic panels and from panels to inverter.
Packaging
Available in rolls (lengths of 50 and 100 m) and coils.
CHARACTERISTICS
INSTALLATION CONDITIONS
Flexible
conductor
class 5/6
Impact resistance
AG2 medium
impact
UV resistant
Photovoltaics
solar installations
Minimum service
tempersture:
-40 ºC
Meter by meter
marking
Water resistance
AD7 immersion
Estimated
lifetime 30
years
Open air
Maximum service
temperature 120ºC
Flame
non-propagation
Chemical & Oil
resistance: good
Grease & mineral
oils resistance:
excellent
For further technical data
please request this cable’s
technical datasheet.
Maximum
short-circuit
temperature:
250ºC (max. 5 s)
91
Minimum bending
radius 3 x cable
diameter
Outdoor installation: occasional
Low extreme
temperature
resistance:
excellent
Abrasion
resistance:
excellent
Top Cable reserves the right
to carry out any modification
whatsoever without giving
previous notice.
National norm / European: EN 60332-1 / EN 50267-1 / EN 50267-2 / EN 61034
International norm: IEC 60332-1 / IEC 60754-1 / IEC 60754-2 / IEC 61034
92