PSB3 Series0 pages
Analog Control Units
PSB3-30024
5
24
m
m
Analog Control Units with
High Capacity of 300 W
110 mm
The PSB3-30024 is a high-capacity (300 W) Analog Control Unit.
Light Unit output is provided for one channel/four connectors (two
metal connectors and two EL connectors). Light intensity can be
set to any of 256 levels, even though the PSB3-30024 is an
Analog Control Unit.Equipped for parallel, serial, or analog control
all in a single Unit. Setting the light intensity has been optimized
via the intensity range switch to select the optimal output for your
Light Units.
97 mm
Weight:
2,300 g
Parallel, Serial, and Analog Control in a Single Unit
Control mode
Description
Parallel communications Light intensity control Control the intensity to 256 levels via parallel signal inputs.
ID switch
ON/OFF input
connector
Set up to 4 Units.
Parallel
communications
connector
EIA-485 communications/
analog input connector
Light intensity control Command input for 256 levels of intensity via EIA-485 communications.
EIA-485
communications(serial) ON/OFF control Command input via EIA-485 communications
Analog input
Light intensity control
ON/OFF input connector
ON/OFF control is possible in combination with parallel, serial, or analog control.
ON/OFF control
Supports the reproducibility of intensity
values through a digital display.
Control the intensity to 256 levels via an analog voltage (0 to 5 V).
ON/OFF control via OFF signal input (parallel bit method).
Optimal Intensity Settings through
Minimum Intensity Value Switching
Intensity range selector
Output voltage
18 to 24 V
15 to 24 V
12 to 24 V
Setting switch
Quick operation through a pushbutton dial
• Intensity setting to any of 256 levels
• Turn ON the power supply while pressing the button for external control mode.
• Push and hold for two seconds to lock the intensity value.
Press to select.
Hold to lock.
Turn to adjust.
Select the intensity range that best suits the Light Unit.
* Output characteristics depend on the Light Unit.
(V)
24
Intensity range
Output voltage
Digital display
18 to 24 V
Intensity range
18
15 to 24 V
Intensity range
15
12
12 to 24 V
0
0
89
64
128
Intensity setting
192
1.25
2.5
3.75
Intensity setting via analog input
255 (Level)
* This graph is for illustration only.
5 (Level)
Direct Number : A direct number is a 7-digit number assigned to a CCS product. You can easily access the web page providing information on any desired product by
simply entering the direct number in the space provided on the CCS website pages for machine vision. (Refer to the back cover of this brochure.)