DMRCD 1 A pulsating AC/DC-sensitive type A0 pages

نسخه متنی
"

Doepke
The experts in residual current protection technology

DATA SHEET
DMRCD 1 A
pulsating AC/DC-sensitive type A
Article No. 09340350

Internetlink

AT
Function
MRCDs (modular residual current devices) consist of a combination of residual current transformer and evaluation unit. In connection
with a separate external circuit-breaker, they allow the implementation of protective measure "Automatic switch-o of power supply" as
per DIN VDE 0100-410 and IEC 60364-4-41. They are primarily useful when no RCCBs or CRBs can be used due to high load currents or
mains voltages. The MRCD detects the residual current and evaluates it in terms of its level and duration. If the residual response current
thresholds and the response time are exceeded, it activates a separate switch-o device that disconnects the system part for which it is
responsible from the power supply. Modular residual current circuit-breakers from series DMRCD have a number of usable total current
transformers and therefore also a number of conductor cross-sections or rated currents. They have one changeover contact and one LED
each for the pre-alarm and main alarm. The bar display provides a view of both the current residual current and the set value for the prealarm. The devices have two response thresholds. The response thresholds for the pre-alarm can be set from 10% to 90% of the response
threshold for the alarm. The set value for the pre-alarm threshold is displayed as a continuously lit LED on the bar display. The alarm is
triggered at a xed response threshold. The current level of the residual current, the response threshold of the pre-alarm and the point
where the response thresholds are exceeded can be seen on a 10-way LED display on the front of the device housing. A faulty connection
to the external residual current transformer is immediately indicated by the alarm LED through a ashing pattern and by the activation of
the signal contacts. The adjustable response delay in the range from 0.1 s to 1 s (in increments of 100 ms) makes it possible to prevent a
response to brief residual current impulses, e.g. lightning strikes and switching overvoltage. This approach allows for selectivity of devices
switched in series, simplifying the localisation of faults. Two independent, potential-free changeover contacts provide the option of
passing on the alarm to optional indicator panels, indicator lights, acoustic signalling devices, touch panels, PLCs, etc. Modular protective
devices with residual current characteristic A detect sinusoidal AC currents as well as pulsating DC residual currents. These devices are
suitable for the monitoring of circuits with frequencies from 50 Hz to 60 Hz. They dier in their adjustment ranges of the residual response
current: The DMRCD 1 A allows settings of 0.03 A, 0.1 A, 0.3 A, 1 A, 3 A, the DMRCD 2 A the adjustment of values 0.03 A, 0.1 A, 0.3 A, 1 A,
10 A.
Features
suitable for detecting type A residual currents, monitored frequency range 50-60 Hz, rated residual operating current can be adjusted at
ve levels, large selection of dierent residual current transformers available, rated currents up to 400 A, rated current can be extended
using DMBT centring sleeve, rated voltage of monitored circuit up to 690 V, with adjustable pre-alarm threshold, with alarm relay,
two potential-free changeover contacts, selectivity adjustable at ten levels, dependent on auxiliary voltage, compact, robust plastic
housingeasy mountingcomplies with DIN EN 60947-2 / VDE 0660-101complies with VDE 0100-410 / IEC 670364-4-41complies with
VDE 0100-530,
Mounting
quick fastening to mounting rail, any installation position
Applications
The monitoring device is suitable for use in power supplied to purpose-built buildings and industrial facilities with TN-S, TN-C-S networks
and IT networks, such as in server rooms for data centres, laboratories, in the automotive industry and in conjunction with air conditioning
systems, printing machines and packaging machines, Not permitted for use in TN-C networks and direct current networks; not permitted
for monitoring systems in which electronic equipment may cause DC residual currents or residual currents with frequencies not equal to
50 Hz.
Notes
Type A residual currents are detected separately by external residual current transformers from series DCT A, which are ordered
separately. No more than one transformer can be operated on one evaluation unit. The VDE certication is only fullled with approved
switch-disconnector combinations and undervoltage trips (see operating instructions). To meet DIN VDE 0100-410, the electrical system
must be isolated from the mains by an external isolating device with a response time of less than 15 ms. The maximum cable length from
the control relay to the transformer is 10 m. If residual currents with frequencies ≠ 50/60 Hz are expected (multiphase operated electronic

2015_03_13

doepke_09340350_dbl_en.pdf

1/3

"

IRAN INDUSTRY EXPO

The largest online Industrial exhibition in Iran

 عضویت ورود   ENGLISH


اگر مجموعه شما جزو صنایع مادر و معظم در فیلد پالایشگاه ، پتروشیمی ، حفاری ، نیروگاه ، معادن و فلزات ، خودروسازی ، تولید مواد غذایی و.... می باشد لطفا درخواست خود را بر روی سربرگ به فاکس 88206264 و یا ایمیل enquiry@iranindustryexpo.com بنام شرکت مهندسی و بازرگانی مشگاد ارسال فرمایید.
اگر مجموعه شما جزو بنگاه های متوسط و کوچک در فیلد تولید ، بازرگانی ، مشاوره ، پیمانکاری ، دانشگاه ، پژوهشگاه ، توزیع ، فروشگاهی وکارگاهی می باشد ، پس از عضویت و با پرداخت هزینه ( به ازای هر درخواست معادل 50 یورو ) از خدمات زیر برخوردار خواهید شد :
  • پاسخ به پرسش های فنی و دریافت مشاوره از سازنده ، دریافت کاتالوگ و اطلاعات تکمیلی
  • دريافت پرفورما از شرکت سازنده
  • اطلاع از زمان تحويل و قيمت خالص كالا
  • اطلاع از هزينه هاي حمل و ترخيص و کارمزد تا تحويل كالا به انبار شما در هر نقطه از كشور
  • دریافت پیش فاکتوررسمی ( ارزی و یا ریالی ) به روش کارمزدی
*صدور پیش فاکتور رسمی فقط به نام شرکتهای ثبت شده که دارای کد بازرگانی معتبر باشند انجام پذیر است. در صورتیکه در حین مکاتبه با شرکت سازنده مشخص شود که دارای نماینده انحصاری و یا شعبه در ایران بوده و یا به به هر دلیل شرکت سازنده از فروش کالا به بازار ایران استنکاف نماید ارایه این سرویس متوقف و وجه دریافتی به حساب کاربر عودت می شود

ادامه