HD series0 pages
DOPAK® Process Sampler Type HD
on/off configuration
The ability to connect the sampler close to the sample point, by
means of an anti static, fire safe process ball valve with reduced
bore and equipped with a spring return handle, ensures optimal
retrieval of a representative, contamination free sample.
The HD type sampler in on/off configuration allows product to
flow directly into the sampler via a two way valve.
1 OPERATION/FUNCTION
0 - off
Provide a new septum on
your sample bottle. Insert the
bottle, with cap and septum
into the sleeve until the
septum is pierced by the
needles. Put the bottle
retaining clip in place.
2 - off
Remove the bottle retaining
clip and pull the bottle out
from the sleeve. The septum
reseals automatically.
2 TYPICAL P & ID
1 - sample
Pull the handle to the
“sample” position, allowing
the product to flow into the
sample bottle. When the
required amount has been
taken, release the handle.
The valve will close
automatically.