LR-Cal FLUID 1000 pages
Portable Temperature Calibration Baths
FLUID 100, FLUID 200 and FLUID 200-H
FLUID 100
FLUID 200
FLUID 200-H
MODELS / Temperature Ranges:
• FLUID 100: from !12°C to +125°C (at 20°C ambient temperature)
• FLUID 200: from ambient temperature to +200°C
• FLUID 200-H: from ambient temperature to +220°C
• Mobile and stationary, ramp function, Thermostat tests
• Recommended for the calibration of glass thermometers
• OPTIONAL conversion kit to Dry Block temp. calibrator
Typical applications:
• Test and calibration of all kind of thermometers
• Test and calibration of thermostats
• Computer aided calibration via RS232-interface
Technical Data:
FLUID 100 / 100-2I
FLUID 200 / 200-2I
Temperature range:
-12°C...+125°C
(at ambient temperature
+20°C)
Ambient temperature
to +200°C
FLUID 200-H: to 220°C
Temp. indication:
Accuracy: ±0.15°C; Resolution 0.01°/0.1° (°C or °F)
Stability of the
regulated temperature:
±0.02°C at !5°C
±0.02°C at 150°C
Mean heating time:
12°C per minute
10°C per minute
Mean cooling time:
5°C per minute
5°C per minute
Uniformity:
temperature uniformity: ±0.05°C (radial and vertical)
Fluid:
Silicone oil 200C5
< 80°C: water
< 125°C: silicone 200C5
< 220°C: silicone 47V100
Bath reservoir:
54 mm diam.
depth 150 mm
54 mm diam.
depth 150 mm
Power supply:
230 VAC / 50 Hz (optional 115 VAC / 60 Hz)
Power consumption:
300 VA
RS232 interface:
yes, included in standard supply
500 VA
Fluid bath: aluminum, volume appr. 400 cm³, homogeny temperature via magnet-mixer, adjustable. Housing: metall; dimensions:
160 x 340 x 330 mm; weight appr. 8 kg. Note: the stated accuracy is valid at ambient temperature +23°C and is guaranteed for
1 year.
Scope of Supply:
C Calibrator Fluid 100 / 200 / 200-H
C Spare fuses kit
C Connection cables for thermostat-tests
C Certificate of Calibration, traceable
C Bottle 500 cm³ with silicone oil
C Support for glass thermometer
• Cables and kit of clamp connections (only “...-2I”-versions)
• Operating manual
• Closing top used for transport
• soft bag
Types FLUID 100-2I , FLUID 200-2I
and FLUID-200-H-2I:
Two inputs for Pt100 and thermocouples, programmable:
C Pt 100 IEC 3-/4-wire, range -100/+700°C, accuracy ±0.3°C
C Thermocouple type J, range 0-1000°C, accuracy ±1°C
C Thermocouple type K/N/R/S, range 0-1300°C, accuracy ±1°C
DRUCK & TEMPERATUR Leitenberger GmbH
Bahnhofstr. 33 C D-72138 Kirchentellinsfurt C Germany
Tel.: +49 - 71 21 - 9 09 20 - 0 C Fax: +49 - 71 21 - 9 09 20 - 99
E-Mail: DT-Export@Leitenberger.de C http://www.druck-temperatur.de
Technische Änderungen vorbehalten. Freibleibend C (Rel. 100121) • All technical modifications reserved. Without engagement