151/RAC0 pages
Cable Glands
151/RAC
Industrial
119
15.0mm 'G' Approx (Fully Compressed Length)
Armour/Braid 'C'
Metric
Entry
Application
Ø 'B'
armour ‘Y’ and steel tape armour ‘Z’ elastomer and plastic insulated cables.
Ø 'A'
Entry Thread
• Outdoor or indoor use.
• For use with single wire armour ‘W’, wire braid ‘X’, aluminium strip
CABLE GLAND SELECTION TABLE
Entry Thread Size
Size Ref.
Metric
Os
O
A
B
C
C2
D
E
F
G
H
J
M20²
M20²
M20
M25
M32
M40
M50
M63
M75
M80
M90
M100
Hexagon
Dimensions
Cable Acceptance Details
Inner
NPT *
Standard Sheath ‘A’
or Option
Max.
½"
8.0
½"
11.9
¾" or ½"
14.3
1" or ¾"
20.2
1¼" or 1"
26.5
1½" or 1¼"
32.5
2" or 1½" 44.4 / 42.3¹
2½" or 2" 56.3 / 54.3¹
3" or 2½" 68.2 / 65.3¹
3½"
72.0
3½"
80.0
4"
90.0
Outer Sheath ‘B’
Min.
5.5
9.5
12.5
16.9
22.0
28.0
36.0
46.0
57.0
75.0
75.0
88.0
'G'
Armour / Braid ‘C’
Max.
12.0
16.0
20.5
26.0
33.0
41.0
52.6
65.3
78.0
89.5
89.5
104.5
Orientation 1
0.8 / 1.25
0.8 / 1.25
0.8 / 1.25
1.25 / 1.6
1.6 / 2.0
1.6 / 2.0
1.8 / 2.5
1.8 / 2.5
1.8 / 2.5
2.0 / 3.5
2.0 / 3.5
2.5 / 4.0
Orientation 2
0.0 / 0.8
0.0 / 0.8
0.0 / 0.8
0.0 / 0.7
0.0 / 0.7
0.0 / 0.7
0.0 / 1.0
0.0 / 1.0
0.0 / 1.0
0.0 / 1.0
0.0 / 1.0
0.0 / 1.0
52.0
52.0
53.0
69.5
64.0
68.3
79.0
78.9
83.7
95.6
95.6
95.6
Across
Flats
Across
Corners
24.0
24.0
30.0
36.0
46.0
55.0
65.0
80.0
95.0
106.4
115.0
127.0
26.5
26.5
32.5
39.5
50.5
60.6
70.8
88.0
104.0
115.0
130.0
142.0
All dimensions in millimetres (except * where dimensions are in inches). Os - F size metric entry threads are 1.5mm pitch as standard, 15mm length of
thread. For G size glands and above, a 2mm pitch is supplied as standard, 20mm length of thread (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering.
¹ Smaller value is applicable when selecting reduced NPT entry option.
² Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable outer sheath diameter is 10.9mm
Features
Technical Data
• Construction and Test Standards: EN 50262, BS 6121 : Part 1
Type CW, CX, CY and CZ.
• Ingress Protection: IP66
to IEC/EN 60529.
• Deluge Protection to DTS01 (Deluge Seal Optional).
• Operating Temperature Range: -60°C to +100°C.
• Assembly Instruction Sheet: AI 393.
• Provides armour clamping using one clamping arrangement for all
armour / braid types.
• Provides a cable retention and low smoke and fume, zero halogen
seal onto the cables outer sheath.
• Manufactured in Brass (standard), Nickel Plated Brass,
316 Stainless Steel or Aluminium.
• Brass NPT entries are nickel plated as standard.
Alternative Reversible Armour Clamping Rings (RAC)
Size Ref.
B
C
C2
D
E
F
SELECTION TABLE
Steel Wire Armour / Braid / Tape
Orientation 1
Orientation 2
0.9 - 1.25
0.5 - 0.9
1.2 - 1.6
0.6 - 1.2
1.2 - 1.6
0.6 - 1.2
1.45 - 1.8
1.0 - 1.45
1.45 - 1.8
1.0 - 1.45
1.45 - 1.8
1.0 - 1.45
Ordering Information
Format for ordering is as follows: Alternative Clamping Ring (AR), add suffix AR to ordering information.
Cable Gland Type
151/RAC
Size
C
Thread
M32
(OPTIONAL)
AR
Cable Gland Type
151/RAC
Size
C
Thread
1 1⁄4"NPT
(OPTIONAL)
AR
Connection Solutions
HPG01
UPD 090610